Paradyne 3350 User Manual page 49

Zhone acculink 3350 ntu: user guide
Hide thumbs Also See for 3350:
Table of Contents

Advertisement

ACCULINK 3350 E1 NTU
Register
Event
Error events counter. An error event is a frame
(Not valid for
with either a Cyclic Redundancy Check (CRC)
Lp n registers.)
error or an Out Of Frame (OOF) event. The
maximum count is 65,535. This register is only
reset as a result of a Clear Performance
Register command. This register is valid for the
current interval only.
CurTimer
Current interval timer. This register records the
number of seconds in the current 15-minute
interval. The maximum is 900 seconds. This
register is valid for the current interval only.
VldIntvl
N/A
ES
The number of errored seconds for the current
interval. An errored second is any second with
one or more of the following: errored frame
alignment, CRC error, Loss of Signal (LOS),
Alarm Indication Signal (AIS), or Loss of Frame
(LOF). The maximum is 900 seconds.
UAS
The number of unavailable seconds for the
current interval. An unavailable second is any
one second interval when service is
unavailable. (Detection occurs with 10
consecutive unavailable seconds.) The
maximum is 900 seconds.
SES
The number of severely errored seconds for the
current interval. For E1 or DTE registers, a
severely errored second is any second with 805
or more CRC errors, 16 or more errored frame
alignment signal events, or one or more LOS,
AIS, or OOF event. For Lp n registers, a
severely errored second is any second with 50
or more CRC6 errors. The maximum is 900
seconds.
BES
The number of bursty errored seconds for the
(Not valid for
current interval. A bursty errored second is any
Lp n registers.)
second with more than one, but less than 805,
CRC errors when in CRC4 mode, or more than
one, but less than 16, errored frame alignment
signals when in non-CRC4 mode. The
maximum is 900 seconds.
4-8
Table 4-4
(1 of 2)
Performance Registers
Interval Description
June 1996
Totals Description
N/A
N/A
Valid interval total. Records the number of valid
15-minute intervals in the previous 24 hours. This
register is not valid for the current interval.
The total number of errored seconds for the previous
24 hours.
The total number of unavailable seconds for the
previous 24 hours.
The total number of severely errored seconds for the
previous 24 hours.
The total number of bursty errored seconds for the
previous 24 hours.
3350-A2-GB20-10