Management Ethernet port
The management Ethernet port is a 10Base-T/100Base-TX/1000Base-T RJ-45 port. It allows you to
upgrade software and manage the router through a network management server without using any
service interface of the router. The management Ethernet port is used only for managing the router
and it has no service processing capabilities such as data forwarding.
Table2-10 Management Ethernet port specifications
Item
Connector
Interface type
Number of interfaces
Frame format
Interface speed and duplex mode
Interface cable and maximum transmission
distance
NOTE:
The media dependent interface (MDI) standard is typically used on the Ethernet port of network
adapters. The media dependent interface crossover (MDI-X) standard is typically used on hubs or
LAN switches.
Combo interface
The MCP provides four combo interfaces.
Table2-11 Copper Ethernet port specifications
Item
Connector
Interface type
Frame format
Interface speed and duplex mode
NOTE:
• The media dependent interface (MDI) standard is typically used on the Ethernet port of network
adapters. The media dependent interface crossover (MDI-X) standard is typically used on hubs
or LAN switches.
• For a combo interface, you can use either the copper port or the fiber port. To switch between the
copper and fiber ports, use the
view.
Specification
RJ-45
Automatic MDI/MDI-X
1
Ethernet_II
Ethernet_SNAP
10 Mbps, half/full-duplex
100 Mbps, half/full-duplex
1000 Mbps, full-duplex
Category-5 twisted pair with a maximum transmission
distance of 100 m (328.08 ft)
Specification
RJ-45
Automatic MDI/MDI-X
Ethernet_II
Ethernet_SNAP
10 Mbps, half/full-duplex
100 Mbps, half/full-duplex
1000 Mbps, full-duplex
combo enable { copper | fiber }