Object Description; Objects For Parameterization - Beckhoff EP4378-1022 Manual

Ethercat box with 4 analog inputs, 4 analog outputs, 8 digital inputs/ outputs
Table of Contents

Advertisement

6.3

Object description

6.3.1

Objects for parameterization

Indices 8100, 8110, 8120, 8130: AI Settings Ch.x
• 8100
AI Settings Ch.1: Settings for the analog input at X01
hex
• 8110
AI Settings Ch.2: Settings for the analog input at X02
hex
• 8120
AI Settings Ch.3: Settings for the analog input at X05
hex
• 8130
AI Settings Ch.4: Settings for the analog input at X06
hex
Access rights: read/write
Subindex
Name
(hex)
01
Enable user scale
02
Presentation
06
Enable filter
07
Enable limit 1
08
Enable limit 2
0A
Enable user
calibration
0B
Enable vendor
calibration
0E
Swap limit bits
11
User scale offset
12
User scale gain
13
Limit 1
14
Limit 2
15
Filter settings
17
User calibration offset Offset value for the User calibration [} 54].
18
User calibration gain
Indices 810D, 811D, 812D, 813D: AI Advanced Settings Ch.n
• 810D
AI Advanced Settings Ch.1: Settings for the analog input at X01
hex
• 811D
AI Advanced Settings Ch.2: Settings for the analog input at X02
hex
• 812D
AI Advanced Settings Ch.3: Settings for the analog input at X05
hex
• 813D
AI Advanced Settings Ch.4: Settings for the analog input at X06
hex
Access rights: read/write
Subindex
Name
(hex)
11
Input Type
12
Scaler
17
Low Range Error
18
High Range Error
EP4378-1022
Description
Enabling User scaling [} 55]
Select the Data format of the measured values [} 47].
Enabling Filter [} 48].
Enabling the Limit value monitoring [} 51] for the limit value
"Limit 1".
Enabling the Limit value monitoring [} 51] for the limit value
"Limit 2"
Enabling User calibration [} 54]
Enabling Vendor calibration [} 53].
Invert comparison operation of the Limit value monitoring
[} 51].
Offset value for the User scaling [} 55].
Gain value for the User scaling [} 55].
Limit value "Limit 1" for the Limit value monitoring [} 51].
Limit value "Limit 2" for the Limit value monitoring [} 51].
Select Select filter type [} 49].
Gain value for the User calibration [} 54].
Description
Set Measuring range [} 43].
Nominal and technical measuring range [} 44].
Error thresholds [} 46].
The Process image [} 24] is set if the measured value is
smaller than this parameter.
Error thresholds [} 46].
The Process image [} 24] is set if the measured value is
smaller than this parameter.
Version: 1.4
CoE parameters
Unit
Data type Default
-
BOOLEA
FALSE
N
-
UINT8
0
-
BOOLEA
FALSE
N
-
BOOLEA
FALSE
N
-
BOOLEA
FALSE
N
-
BOOLEA
FALSE
N
-
BOOLEA
TRUE
N
-
BOOLEA
FALSE
N
-
INT16
0
-
INT32
65536
dec
-
INT16
0
-
INT16
0
-
UINT16
2
-
INT16
0
-
INT16
16384
dec
Unit
Data type Default
-
UINT16
2
-
UINT16
0
-
INT32
-32768
-
INT32
32767
dec
dec
69