Calibration And Scaling - Beckhoff EP4378-1022 Manual

Ethercat box with 4 analog inputs, 4 analog outputs, 8 digital inputs/ outputs
Table of Contents

Advertisement

5.2.6

Calibration and scaling

5.2.6.1
Vendor calibration
Each analog input is calibrated in the factory. The results of the calibration are the coefficients of a correction
function. The correction function is:
Y
= G
* ( X
- O
V
V
V
The coefficients G
and O
V
the user calibration [} 54].
You will find the coefficients for the different measuring ranges in the following CoE objects:
Connection
CoE object (read only)
X01
810F
X02
811F
X05
812F
X06
813F
Disabling the vendor calibration
Measuring error with disabled vendor calibration
The measuring error specified in the technical data [} 13] is no longer guaranteed if you disable the vendor
calibration.
If you use the user calibration, it may be a good idea to disable the vendor calibration.
Set the following CoE parameters to FALSE to disable the vendor calibration for the respective input.
Connection
CoE object
X01
8100
X02
8110
X05
8120
X06
8130
EP4378-1022
)
V
cannot be changed by the user. If you wish to carry out a calibration yourself, use
V
AI Vendor data Ch.1
hex
AI Vendor Data Ch.2
hex
AI Vendor data Ch.3
hex
AI Vendor data Ch.4
hex
AI Settings Ch.1
hex
AI Settings Ch.2
hex
AI Settings Ch.3
hex
AI Settings Ch.4
hex
Version: 1.4
Y
: Measured value after the vendor calibration
V
X
: Measured value before the vendor calibration
V
G
: Gain of the vendor calibration
V
O
: Offset of the vendor calibration
V
NOTICE
Parameter
0B
hex
0B
hex
0B
hex
0B
hex
Commissioning and configuration
Enable vendor calibration
Enable vendor calibration
Enable vendor calibration
Enable vendor calibration
53

Advertisement

Table of Contents
loading

Table of Contents