Sign In
Upload
Manuals
Brands
Beckhoff Manuals
Industrial Electrical
KL2819
Beckhoff KL2819 Manuals
Manuals and User Guides for Beckhoff KL2819. We have
3
Beckhoff KL2819 manuals available for free PDF download: Documentation
Beckhoff KL2819 Documentation (42 pages)
HD Bus Terminal, 16-channel digital output 24 V DC, with diagnostics
Brand:
Beckhoff
| Category:
I/O Systems
| Size: 2.87 MB
Table of Contents
Table of Contents
3
Foreword
5
Notes on the Documentation
5
Safety Instructions
6
Documentation Issue Status
7
Product Overview
8
Introduction and Contact Assignment
8
Fig. 1 KL2819
8
Technical Data
10
Overload Protection
10
Fig. 2 Overload Current Limitation
11
Fig. 3 Schematic Illustration of the Thermal Switch-Off in Case of Overload
11
Fig. 4 Switch-Off of Inductive Loads
12
Interference-Free Bus Terminals
13
Fig. 5 Negative Example - Active Load
14
Fig. 6 Ground Connection of the Load: Correct (K1) and Incorrect (K2)
15
Fig. 7 Short Circuit Fault Exclusion through Protected Cable Laying
16
Mounting and Wiring
17
Instructions for ESD Protection
17
Fig. 8 Spring Contacts of the Beckhoff I/O Components
17
Installation on Mounting Rails
18
Fig. 9 Attaching on Mounting Rail
18
Fig. 10 Disassembling of Terminal
19
Fig. 11 Power Contact on Left Side
20
Fig. 12 Standard Wiring
21
Fig. 13 Pluggable Wiring
21
Connection System
21
Connection
21
Fig. 14 High Density Terminals
22
Wiring
23
Fig. 15 Connecting a Cable on a Terminal Point
23
Shielding
24
Installation Positions
24
Fig. 16 Recommended Distances for Standard Installation Position
25
Disposal
26
Fig. 17 Other Installation Positions
26
KS2000 Configuration Software
27
KS2000 - Introduction
27
Fig. 18 KS2000 Configuration Software
27
Fig. 19 Display of the Fieldbus Station in KS2000
28
Parameterization with KS2000
28
Fig. 20 KS2000 Tree Branches for Channel 1 of the KL2819
29
Register
30
Fig. 21 Register View in KS2000
30
Access from the User Programm
31
Control and Status Bytes
31
Process Data Mode
31
Register Communication
31
Register Overview
32
Register Description
33
Examples of Register Communication
35
Example 1: Reading the Firmware Version from Register 9
35
Example 2: Writing to an User Register
35
Appendix
39
Support and Service
39
Table of Figures
40
Advertisement
Beckhoff KL2819 Documentation (34 pages)
HD Bus Terminals, digital output 24 V DC
Brand:
Beckhoff
| Category:
Touch terminals
| Size: 0.66 MB
Table of Contents
Table of Contents
4
2 Foreword
5
Notes on the Documentation
5
Safety Instructions
6
Documentation Issue Status
7
Non-Reactive Bus Terminals
7
3 KL2808 - Introduction and Technical Data
8
Introduction and Pin Assignment
8
Fig. 1 KL2808
8
Technical Data
10
4 KL2828 - Introduction and Technical Data
11
Introduction and Pin Assignment
11
Fig. 2 KL2828
11
Technical Data
13
5 KL2809, KL2889 - Introduction and Technical Data
14
Introduction and Pin Assignment
14
Fig. 3 KL2809
14
Fig. 4 KL2889
14
Technical Data
16
6 KL2872, KL2872-0010 - Introduction and Technical Data
17
Introduction and Pin Assignment
17
Technical Data
17
Fig. 5 KL2872
17
Fig. 6 KL2872-0010
18
Fig. 7 Dimensions of the 20-Pin Contact Strip of the Terminal and the Matching Spring Contact Strip; for Connections See Contact Assignment
19
7 KL2819 - Introduction and Technical Data
20
Introduction and Pin Assignment
20
Fig. 8 KL2819
20
Technical Data
22
Continuing Documentation
22
8 Mounting and Wiring
23
Installation on Mounting Rails
23
Fig. 9 Attaching on Mounting Rail
23
Fig. 10 Disassembling of Terminal
24
Installation Instructions for Enhanced Mechanical Load Capacity
25
Fig. 11 Power Contact on Left Side
25
Connection System
26
Fig. 12 Standard Wiring
26
Fig. 13 Pluggable Wiring
27
Fig. 14 High Density Terminals
27
Fig. 15 Mounting a Cable on a Terminal Connection
28
Installation Positions
29
Fig. 16 Recommended Distances for Standard Installation Position
29
Fig. 17 Other Installation Positions
30
ATEX - Special Conditions
31
ATEX Documentation
32
9 Appendix
33
Support and Service
33
List of Illustrations
34
Beckhoff KL2819 Documentation (31 pages)
HD Bus Terminal, 16-channel digital output 24 V DC, with diagnostics
Brand:
Beckhoff
| Category:
Industrial Electrical
| Size: 0.66 MB
Table of Contents
Table of Contents
3
1 Foreword
4
Notes on the Documentation
4
Safety Instructions
5
Documentation Issue Status
6
Non-Reactive Bus Terminals
6
2 KL2819 - Introduction and Technical Data
7
Introduction and Pin Assignment
7
Fig. 1 KL2819
7
Technical Data
9
Overload Protection
9
Fig. 2 Overload Current Limitation
10
Fig. 3 Schematic Illustration of the Thermal Switch-Off in Case of Overload
10
Fig. 4 Switch-Off of Inductive Loads
11
3 Mounting and Wiring
12
Installation on Mounting Rails
12
Fig. 5 Attaching on Mounting Rail
12
Fig. 6 Disassembling of Terminal
13
Connection System
14
Fig. 7 Power Contact on Left Side
14
Fig. 8 Standard Wiring
15
Fig. 9 Pluggable Wiring
15
Fig. 10 High Density Terminals
15
Fig. 11 Mounting a Cable on a Terminal Connection
16
Installation Positions
17
Fig. 12 Recommended Distances for Standard Installation Position
18
ATEX - Special Conditions
19
Fig. 13 Other Installation Positions
19
ATEX Documentation
20
4 KS2000 Configuration Software
21
KS2000 - Introduction
21
Fig. 14 KS2000 Configuration Software
21
Register
22
Fig. 15 Register View in KS2000
23
5 Access from the User Programm
24
Control and Status Bytes
24
Process Data Mode
24
Register Communication
24
Register Overview
26
Register Description
27
6 Appendix
30
Support and Service
30
List of Illustrations
31
Advertisement
Advertisement
Related Products
Beckhoff KL2784
Beckhoff KL2692
Beckhoff KL27 2 Series
Beckhoff KL2701 Series
Beckhoff KL2701-0000
Beckhoff KL2702-0000
Beckhoff KL2702-0020
Beckhoff KL2702-0002
Beckhoff KL2712-0000
Beckhoff KL2722-0000
Beckhoff Categories
Touch terminals
Industrial PC
Control Unit
Touch Panel
Power Supply
More Beckhoff Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL