Safety Characteristic Data - Pilz PNOZ m B0.1 Operating Manual

Table of Contents

Advertisement

Technical details
10.1

Safety characteristic data

Unit
Operating
mode
Logic
CPU
2-channel PL e
Expansion
left
Expansion
right
Input
Inputs
1-channel PL d
Inputs
2-channel PL e
Inputs
Short cir-
cuit-form-
ing safety
mats
Inputs
1-ch.,
pulsed
light bar-
rier
Output
SC outputs 1-channel
with re-
duced
fault de-
tection
SC outputs 2-channel
with re-
duced
fault de-
tection
SC outputs 1-channel
with ad-
vanced
fault de-
tection
SC outputs 1-channel PL d
Operating Manual PNOZ m B0.1
1005720-EN-04
NOTICE
You must comply with the safety characteristic data in order to achieve the
required safety level for your plant/machine.
EN ISO
EN ISO
13849-1:
13849-1:
2015
2015
PL
Category
Cat. 4
PL e
Cat. 4
PL e
Cat. 4
Cat. 2
Cat. 4
PL d
Cat. 3
PL e
Cat. 4
PL d
Cat. 2
PL e
Cat. 4
PL e
Cat. 4
Cat. 2
EN IEC
EN IEC
62061
62061
SIL CL/
PFH
[1/h]
D
maximum
SIL
SIL 3
4,74E-10
SIL 3
3,30E-11
SIL 3
2,79E-11
SIL 2
3,85E-09
SIL 3
7,95E-11
SIL 2
1,06E-09
SIL 3
3,85E-10
SIL 2
2,45E-09
SIL 3
4,87E-09
SIL 3
1,66E-11
SIL 2
1,57E-10
EN/IEC
EN/IEC
61511
61511
SIL
PFD
SIL 3
4,00E-05
SIL 3
2,49E-06
SIL 3
2,18E-06
SIL 2
3,38E-04
SIL 3
6,90E-06
SIL 2
9,14E-05
SIL 3
3,40E-05
SIL 2
1,04E-04
SIL 3
2,06E-04
SIL 3
1,46E-06
SIL 2
1,35E-05
EN ISO
13849-1:
2015
T
[year]
M
20
20
20
20
20
20
20
20
20
20
20
| 41