Type 3363, 3364, 3365
Installing the valve
7.1.2 Installation position for T-body
Recommended installation position:
For supply of medium
Fig. 11: Installation position for T-body, Type 3364
7.1.3 Installation position for tank bottom body
Recommended installation position: Preferably with actuator
facing downwards.
Fig. 12: Installation position for tank bottom body, Type 3365
For removal of medium
7.2
Installation of devices with threaded
connection, flange connection, clamp
connection, bonded connection
NOTE!
Damage to the diaphragm.
▶ To avoid damage, the device must be in MANUAL operating
state during installation.
Devices in their factory default state already have their operating
state set to MANUAL.
Installation conditions
Pipelines: E nsure the pipelines are aligned.
Preparation:
S upport and align pipelines.
An inclination angle of 1°...5° must be observed
for the pipeline to enable self-drainage.
DANGER!
Risk of injury from high pressure.
▶ Before working on the system, switch off the pressure and
vent or empty the lines.
→
Connect valve body to pipeline.
Ensure that there is no voltage present and minimal vib-
ration during installation.
Holding device: To protect the valve actuator from
damage resulting from forces and vibrations, a holding
device is recommended. This is available as an accessory.
See operating instructions on the website country.burkert.
com
english
19