Installation Of Devices With Threaded Connection, Flange Connection, Clamp Connection, Bonded Connection - Burkert AE3363 Quick Start Manual

Electromotive diaphragm control valve
Table of Contents

Advertisement

Available languages

Available languages

Type 3363, 3364, 3365
Installing the valve
7.1.2 Installation position for T-body
Recommended installation position:
For supply of medium
Fig. 11: Installation position for T-body, Type 3364
7.1.3 Installation position for tank bottom body
Recommended installation position: Preferably with actuator
facing downwards.
Fig. 12: Installation position for tank bottom body, Type 3365
For removal of medium
7.2
Installation of devices with threaded
connection, flange connection, clamp
connection, bonded connection
NOTE!
Damage to the diaphragm.
▶ To avoid damage, the device must be in MANUAL operating
state during installation.
Devices in their factory default state already have their operating
state set to MANUAL.
Installation conditions
Pipelines: E nsure the pipelines are aligned.
Preparation:
S upport and align pipelines.
An inclination angle of 1°...5° must be observed
for the pipeline to enable self-drainage.
DANGER!
Risk of injury from high pressure.
▶ Before working on the system, switch off the pressure and
vent or empty the lines.
Connect valve body to pipeline.
Ensure that there is no voltage present and minimal vib-
ration during installation.
Holding device: To protect the valve actuator from
damage resulting from forces and vibrations, a holding
device is recommended. This is available as an accessory.
See operating instructions on the website country.burkert.
com
english
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae3364Ae3365Ae33336333643365

Table of Contents