7.1.2 Installation position for T-body
Recommended installation position:
For supply of medium
Fig.11:
Installation position for T-body, Type 3324
7.1.3 Installation position for tank bottom body
Preferably actuator facing downwards.
Fig.12:
Installation position of Type 3325
18
For removal of medium
English
Type 3323, 3324, 3325
Installing the valve
7.2
Installation of devices with threaded
socket connection, flange connection,
clamp connection and bonded
connection
NOTE!
Damage to the diaphragm.
▶ To avoid damage, the valve must be in MANUAL operating
state during installation.
Devices in their factory default state already have their ope-
rating state set to MANUAL.
Installation conditions:
Pipelines:
Ensure the pipelines are aligned.
Preparation:
Support and align pipelines. For self-draining,
maintain an angle of inclination of 1°...5° for the
pipeline.
DANGER!
Risk of injury from high pressure.
▶ Before working on the system, switch off the pressure and
vent or empty the lines.
→ Connect valve body to pipeline.
Ensure that there is no voltage present and minimal vib-
ration during installation.