XII. TROUBLESHOOTING
Error Code
E01
E02
E03
E04
E05
E06
Description
Overcurrent Protection
Hall Error
Hardware overcurrent
Phase loss
Under voltage
Overvoltage
Troubleshooting Methods
1. The possible reason is that the current ex-
ceeds the rated load, and the system protects
itself. Restart the treadmill.
2. The treadmill has detected an obstruction in
a specific component or is overheated, prevent-
ing the smooth rotation of the treadmill. The
self-protection mechanism has been activated
to prevent potential damage. To resolve this
issue, either restart the treadmill or consider
applying additional lubrication to facilitate
smoother operation.
3. Check for abnormal sounds or burning smells
during motor operation; replace motor if neces-
sary.
4. Replace the controller.
1. Check if the motor wire is properly connected
and reconnect the motor wire.
2. Replace the motor.
3. Replace the controller.
1. The possible reason is that the current ex-
ceeds the rated load, and the system protects
itself. Restart the treadmill.
2. Check whether the source socket and motor
connection are loose.
3. Replace the controller.
1. Check if the motor wire is properly connected
and reconnect the motor wire.
2. Replace the motor.
3. Replace the controller.
1. Check whether the source is normal.
2. Check whether the source socket plug is
loose.
1. Check whether the source is normal.

TROUBLESHOOTING |

27