Troubleshooting - LifeSpan Delta 1.0 User Manual

Table of Contents

Advertisement

XII. TROUBLESHOOTING
Error Code
E01
E02
E03
E04
E05
E06
E07
E12
E13
E14
24

| TROUBLESHOOTING

Description
Hardware error includes
Hardware overcurrent
protection
IPM over-temperature protec-
tion
low-voltage protection
Overvoltage protection
Motor open-phase protection
Motor reverse protection
Motor overcurrent protection
Overload protection
Hall error protection
Solution
1. Check if the connection between the power
socket plug and the motor is loose.
2. Replace the controller.
1. The possible reason is that the current ex-
ceeds the rated load, so the system can protect
itself and restart.
2. Check if the power socket plug and the motor
connection are loose.
3. Replace the controller.
1. Turn off the power and turn it on again when
the temperature drops.
2. Replace the controller.
1. Check whether the input power supply voltage
is normal.
1. Check whether the input power supply voltage
is normal.
1. Check if the motor cable is connected properly
and reconnect the motor cable.
2. Replace the motor.
3. Replace the controller.
1. Check if the motor wire is connected properly.
1. Power off and power on again.
2. Check whether the connection between the
power socket plug and the motor is loose.
3. Replace the controller.
1. The possible reason is that the current ex-
ceeds the rated load, so the system can protect
itself and restart.
2. A certain part of the treadmill is stuck, caus-
ing the motor to fail to rotate, the load is too
heavy, the current is too large, and the system
protects itself. Just adjust the treadmill to re-
start or add lubricating oil.
3. Check whether there is an over-current sound
or burning smell when the motor is running and
replace the motor.
4. Replace the controller.
1. Check whether the motor cable is connected
properly and reconnect the motor cable.
2. Replace the motor.
3. Replace the controller.