Room Dimensions Required For A Single Docutech Installation; Single Docutech System Without An Interposer - Xerox DocuTech 6100 Install Manual

Xerox docutech 6100: install guide
Hide thumbs Also See for DocuTech 6100:
Table of Contents

Advertisement

Select and prepare an installation site
Table 4-1. Physical dimensions for the DocuTech 6100, 6115, and 6135
Total space
Refer to the following footprint
requirement
diagrams

Room dimensions required for a single DocuTech installation

Single DocuTech system without an Interposer

4-2
Table 4-2. Physical dimensions for the DocuTech 6155
Dimension
Width
Depth
Height
Weight
DocuSP Controller Stand
(optional)
Total space requirement
The printer must be installed in a fixed location that provides the
following clearance space:
36 inches (910 mm) of clearance in back of each component.
78 inches (1980 mm) of vertical clearance throughout the
entire area.
50 inches (1270 mm) of exclusive operator/service area in
front of each component.
33 inches (825 mm) to the left of the printer to accommodate
the DocuSP controller with or without the stand.
When installing a single DocuTech system without an Interposer,
the clearance space shown in the following diagram must be
maintained.
Refer to following footprint diagrams
and 6180
Specification
180 inches (457 cm)
36 inches (91 cm)
48 inches (122 cm)
3227 pounds (1465 kg)
NOTE: Ensure that the floor is level
and strong enough to support the
weight of the system.
30 inches x 30 inches
Refer to following footprint diagrams
DocuTech 61xx Installation Planning Guide