Technical Data - Profinet Rt; Profinet Device Integration Under Twincat 2.11 - Beckhoff EL6631-0010 Manual

Profinet device supplement
Table of Contents

Advertisement

5.2
TwinCAT 2.11
5.2.1

Technical data - PROFINET RT

When using TwinCAT 2.11, all the target systems, for instance the CX Controllers, must have TwinCAT
version 2.11 installed.
Technical data
PROFINET Version
Number of device interfaces )
Topology
Quantity of user data
Cycle time
1
)
see the chapter on virtual PROFINET devices
2
)
Depending on the cycle time, the PROFINET cycle time, and the CPU being used
Conditions required for operation
The following points must be observed when using the PROFINET supplement:
• Only Ethernet cards with Intel chipset allowed.
• RealTime Ethernet driver must be installed.
• No other RealTime protocols must be connected through this interface.
• The real-time capability can only be guaranteed in the transmit direction; in the receive direction,
the possibility of incorrect use means that it cannot be guaranteed. This might, for example, be
the copying of large quantities of data through this interface.
It is recommended that the PROFINET network is separated from other networks.
5.2.2

PROFINET device integration under TwinCAT 2.11

This description applies to the PROFINET DEVICE Supplement.
Installation
For a correct installation at least TwinCAT 2.11 build 1546 should be installed. With older TwinCAT
versions we recommend an update. In other cases please contact Beckhoff Support [} 80].
1. Integration of the PROFINET protocol
A PROFINET device must first be added.
EL6631-0010
Supplement
RT Class 1 ConformanceClassB
1
8
variable
per device, maximum one Ethernet frame length )
1500 bytes of user data, inc. IOPS and IOCS
≥ 1 ms
Version: 3.4.0
TwinCAT supplement
2
49