07/ Error Information - ACME TORNADO User Manual

Table of Contents

Advertisement

Error codes are shown continuously in the display when the fixture fails and they will not
CPU-B/C/D/E/F/G/H Error
LED Timeout Use
LED Too Hot Off
LED Temp. 1/2/3/4/5 Error
Network Error

07/ Error Information

disappear until the fixture is repaired.
Check whether the 485 (DATA) leads on the PCB board are installed in
place or disconnected.
Check whether the related 485 (DATA) signal circuit on the PCB board
is damaged.
When the fixture temperature reaches 85℃, it will automatically turn
off to protect the fixture.
Check whether the temperature detecting board is normal.
Check whether the components of the temperature detecting board
are damaged.
Check whether the lead on the temperature detecting board is
installed in place or disconnected.
Check whether the net model is installed in place.
Check whether the net model is damaged.
Check whether the network is normal.
- 45 -