Error codes are shown continuously in the display when the fixture fails and they will not
CPU- B/C/D/E Error
Pan Reset Error
Pan Encode Error
07/ Error Information
disappear until the fixture is repaired.
Check whether the 485 (DATA) leads on the PCB board are installed in
place or disconnected.
Check whether the related 485 (DATA) signal circuit on the PCB board
is damaged.
Check whether the position of the pan where the magnet is installed
falls off or is damaged.
Check whether there are obstacles in the pan operating range.
Check whether the Hall element on the pan is damaged.
Check whether the lead connecting the Hall element on the pan and
the PCB board is in poor contact or disconnected.
Check whether the motor on the pan is damaged.
Check whether the related circuit of the motor drive board on the pan
is damage.
Check whether the encoder on the pan is damaged.
Check whether the lead connecting the encoder on the pan and the
PCB board is in poor contact or disconnected.
- 47 -