Commissioning; Technical Data - Gira 0309 00 Operating Instructions Manual

Electronic potentiometer insert for 1-10 v control input, switching function

Advertisement

Electronic potentiometer insert for 1-10 V control input, switching function
CAUTION!
Device defect when the 1-10 V interface is connected to mains voltage
Do not connect 1-10 V interface to mains voltage.
Connect electronic potentiometer with switching function according to connec-
tion diagram (see figure 2) or (see figure 3).
If multiple circuit breakers supply dangerous voltages to the device or load,
couple the circuit breakers or label them with a warning, to ensure disconnec-
tion is guaranteed.
Fit device in appliance box; terminals must be at the bottom.
Adjusting basic brightness
Mount the frame and the central plate.
Attach the control button.
7

Commissioning

Adjusting basic brightness
DANGER!
Electric shock when live parts are touched.
Electric shocks can be fatal.
Use only insulated tools to set the basic brightness! Cover up live parts in the work-
ing environment.
The basic brightness can be set by an electrically skilled person as required.
The device is connected as described above and fitted in an appliance box. The
frame, central plate and control button are not fitted.
Switch on mains voltage.
Press the rotary axle to switch on the lighting and turn it left to the minimum
brightness.
Adjust basic brightness by turning the adjuster (7) (see figure 1). The basic
brightness must be set in such a way that the connected lamps are still visibly
lit when the control button is turned all the way to the left.
8

Technical data

Rated voltage
Mains frequency
Ambient temperature
Switching current for AC 230/240 V~
Ohmic
32406702
10869716
30.06.2023
AC 230 / 240 V ~
50 / 60 Hz
+5 ...+25 °C
6 A