Gira 2100 Series Operating Instructions Manual

Gira 2100 Series Operating Instructions Manual

Continuous regulator
Hide thumbs Also See for 2100 Series:

Advertisement

Quick Links

Operating instructions
Continuous regulator
Order no. 2100 ..
Product image non-binding

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2100 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gira 2100 Series

  • Page 1 Operating instructions Continuous regulator Order no. 2100 .. Product image non-binding...
  • Page 2: Table Of Contents

    Continuous regulator Table of contents Safety instructions ...................... 3 Device components ...................... 3 Function .......................... 4 Operation ..........................  4 Information for electrically skilled persons ................  6 Mounting and electrical connection................  6 Commissioning ......................  8 Appendix...........................  9 Technical data...................... 9 Accessories...................... 9 Warranty ........................
  • Page 3: Safety Instructions

    Continuous regulator Safety instructions Electrical devices may be mounted and connected only by electrically skilled persons. Serious injuries, fire or property damage are possible. Please read and follow the manual fully. Danger of electric shock at the KNX installation. Do not connect any external voltage to the inputs.
  • Page 4: Function

    Continuous regulator Function Intended use – Single-room temperature control in KNX installations – Load types: LED or electronic relay – Mounting in appliance box with dimensions according to DIN 49073 Product characteristics – Measurement of the room temperature and comparison with the setpoint tem- perature –...
  • Page 5 Continuous regulator ¾ Frost/heat protection operating mode Comfort extension / night operating mode 0¾ Comfort extension / frost / heat protection operating mode Heating/cooling indication active Heating mode indication Cooling mode indication Controller blocked indication, dewpoint operation Setting the operating mode Operating elements for setting the operating mode via the bus are installed, e.g.
  • Page 6: Information For Electrically Skilled Persons

    Continuous regulator Information for electrically skilled persons Mounting and electrical connection DANGER! Electric shock when live parts are touched. Electric shocks can be fatal. Cover up live parts in the installation environment. Mounting notes Do not use controllers in multiple combinations with electrical devices. Their heat de- velopment will influence the temperature measurement of the controller.
  • Page 7 Continuous regulator Programming LED Programming button ■ Separate the connection terminal insert (4) and the electronics cover (6) (see figure 2). ■ Connect the bus line to the device connection terminal (11) in the connection terminal insert (see figure 3). Figure 3: Connection terminal insert ■...
  • Page 8: Commissioning

    Continuous regulator Figure 5: Connection of binary outputs Optional: Route an external temperature sensor in an empty pipe and guide the sensor head out at the measurement location. Select the installation location for the temperature sensor so that it can measure the temperature without any influence from sources of interference.
  • Page 9: Appendix

    Please submit or send faulty devices postage paid together with a fault de- scription to your responsible salesperson (specialist trade / installation company / electrical specialist trade). They will forward the devices to the Gira Service Center. Gira Giersiepen GmbH & Co. KG...
  • Page 10 Continuous regulator Deutschland Tel +49(0)21 95 - 602-0 Fax +49(0)21 95 - 602-191 www.gira.de info@gira.de 32561932 10871292 22.01.2024 10 / 10...

Table of Contents