F4 - SETUPS
• F4 opens the machine settings menu where more in-depth options can be accessed.
• Navigate using the arrow keys then use the number pad to enter values.
• F1 Speed opens some common settings. Shown in (FIG 36), these settings are relevant to all modes.
- Start speed (mm/min) - Speed at which movement starts. Can be used to slowly ramp up the movement speed over the time defined below in
Acc time (S). Useful for thicker materials and making precise manual movements easier.
- Acc time (S) - Time period over which the Start speed (mm/min) accelerates to the operating speed and decelerates to zero.
- Acceleration (S) - Changes the speed at which the stepper motors accelerate. This controls how "jumpy" or "sharp" sudden changes direction,
such as corners, will be. Small adjustments here make a big difference, 0.3s is a good middle ground.
- G00 move speed (mm/min) - Speed used when the table automatically traverses the torch.
- Return origin speed (mm/min) - This setting is unused in the current table configuration.
- Demo/back Speed (mm/min) - Speed used when running in demo mode or utilizing the Back function.
- Spd Tran Angle - This setting is unused in the current table configuration.
- Corner Radius (mm) - This setting is unused in the current table configuration.
- Small Arc Limit (mm/min) - Speed limit when cutting a radius less than the size set below in Limited Speed below Radius (mm). Can improve radius
quality by slowing the torch down.
- Limited Speed below Radius (mm) - Any radius equal to or smaller than this setpoint will reduce speed to the limit defined in Small Arc Limit
(mm/min) above.