• F4 Plasma opens the plasma specific settings menu shown in (FIG 38).
- Position Check (0/1) - This option enables or disables running of the initial height program. Leave set to "1" to run the program before cutting so the
torch levels itself.
- Position Up Time (S) - This is the Initial Height Setting motor run up-time in seconds. This is also adjustable from the main cut screen with keys
4 and 5.
- Torch Up Time (M70) - The amount of time the torch height motor will run upward at the beginning and end of a cut path. Set to zero or a fraction of
second to save time.
- Torch Down Time (M71) - The amount of additional time the torch will run down before starting a cut path. Set to zero or a fraction of a second
to save time.
- Watch Arc Enable (0/1) - Setting to "1" enables monitoring of the plasma arc via arc voltage, used in conjunction with the following two settings
below. When set to "0" the table will not stop if arc voltage is undetected.
- Arc Start Detect (S) - Pausing time of arc detection when the cut starts. The table will not pause if it detects the arc is lost in this time period.
- Arc Loss Delay (S) - Arc loss detection delay. If the table detects the arc is lost for longer than the set time, it will pause cutting and display an
arc alarm. Normally left at zero.
- Pierce Time (S) - The amount of time after arc start the Plasma Torch will remain stationary in order to pierce the material before moving.
- Arc Off Delay Time (S) - Pauses the table for the set number of seconds after turning off the plasma arc. Can be used to space time between cuts
on a part with many holes, if desired. Otherwise set to zero or a fraction of a second to save time.
- Time to lock THC (S) - Time period it will lock the THC after cut start. Helpful for odd starts with large gaps, or on thick material that results in an
unstable arc when starting the cut.
- Distance to lock THC (mm) - Distance from the end of the cut segment the THC will be locked.
- Speed to lock THC (mm/min) - If the movement speed during cutting is below this point it will lock the torch height.
- Distance to Off arc before end of cutting (mm) - Distance before the end of cutting that it will turn the plasma arc off.
- Distance to Lock THC before end of cutting (mm) - Distance before the end of cutting that it will lock the torch height.
- Use Cylinder THC (0/1) - This setting is for other types of height controller. Leave set to "0" for this table.
FIG. 38
28