Mitsubishi Electric MELSEC-FX3S Series Manual page 370

Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
FX
-3A-ADP (2-channel Analog Input, 1-channel Analog Output)
3U
3. Example of program 2 (FX
For example, create the following program to change the digital output data (D120) of the 1st analog special
adapter.
M8001
Normally
OFF
FNC230
D120
LD>=
M20
H-36
PLC User's Manual - Analog Control Edition
3UC
/FX
3S
3G
FNC237
K0
AND<=
FNC 22
MUL
FNC 23
DDIV
FNC 20
ADD
FNC 12
MOV
5 Changing of Input/output Characteristics
5.2 Example: Changing of Voltage Output Characteristics
/FX
Series PLC)
3GC
M8282
M8286
D120
K10000
M20
D120
K1600
D121
D121
K10000 D123
D123
K400
D127
D127
D8282
Sets the output mode to the voltage
output mode (0 V to 10 V).
Sets the output holding function.
Check to make sure the digital
value (D120) is in range.
Calculation for changing output
characteristics.
Stores the operation result in D8282.