Video service monitor Alarm connector Mounting Lens mounting Mounting the camera Quick set-up Back focus adjustment Accessing and navigating quick set-up menu 4.2.1 How to use the navigation keys Bosch Security Systems Operating Instructions | en 3 V 2.5 | 2007.6...
Page 4
Configuration via the browser Settings General Settings 7.2.1 Camera identification 7.2.2 Password protection 7.2.3 Language selection 7.2.4 Date and time 7.2.5 Time server Display Settings 7.3.1 Display stamping Encoder Settings V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Deleting partitions Recording profile 7.10 Recording scheduler 7.10.1 Activating recording 7.10.2 Recording status 7.11 Alarm Settings 7.11.1 Alarm in 7.11.2 Alarm connections 7.12 7.12.1 Analysis 7.12.2 Analysis type Bosch Security Systems Operating Instructions | en 5 V 2.5 | 2007.6...
Page 6
Connect on alarm 8.0.4 Connecting with a Web browser 8.0.5 Closing the connection Operation with decoder software Maintenance 10.1 Testing the network connection 10.2 Repairs 10.2.1 Transfer and disposal V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Page 7
Dinion IP Troubleshooting Specifications 12.1 Dimensions (mm/inch) 12.2 Accessories 12.2.1 Recommended lenses 12.2.2 Power transformers Glossary Bosch Security Systems Operating Instructions | en 7 V 2.5 | 2007.6...
For units intended to operate with V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Page 9
– – – – – Bosch Security Systems For battery powered units, refer to the operating instructions. For external power supplied units, use only the rec- ommended or approved power supplies. For limited power source units, this power source must comply with EN60950.
Page 10
14. Attachments, changes, or modifications - Only use attach- ments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warrantee or, in the case of an authorization agreement, authority to operate the equipment.
Page 11
The exclamation point within the triangle sign alerts the user to important instructions accompanying the unit. CAUTION! Alerts the user to the risk of damage to the unit. NOTE! General sign for notes. Calls attention to important information. Bosch Security Systems Operating Instructions | en 11 V 2.5 | 2007.6...
Page 12
Video loss Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recom- mends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
Page 13
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFI- CATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNC- TIONS OF THIS PRODUCT. Bosch Security Systems reorient or relocate the receiving antenna; increase the separation between the equipment and receiver;...
Page 14
Please dispose of these units at an environmentally compatible recycling facility, per European Directive 2002/96/EC. Bosch has a strong commitment towards the environment. This unit has been designed to respect the environment as much as possible.
– Fast, convenient configuration using the integrated Web server and a browser – Firmware update through flash memory – Convenient upload and download of configuration data Bosch Security Systems Operating Instructions Introduction | en 15 V 2.5 | 2007.6...
24 VAC or 12 VDC (use class 2 power supply) or PoE (IEEE 802.3af) 1/3" IP camera Manual System requirements Configuration Manager MPEG ActiveX control DirextX control Microsoft Internet Explorer Sun JVM Player and archive player Adobe Acrobat Reader Operating Instructions Dinion IP NWC-0455-20P 60 Hz Bosch Security Systems...
VIDOS, BMVS or DIBOS 8.0 – MPEG-4 compatible hardware decoder from Bosch Security Systems (such as VIP XD) as a receiver and a connected video monitor The minimum PC requirements are: – Operating platform: A PC running Windows 2000 or Win- dows XP with IE 6.0...
LAN, and an additional JPEG stream for use with a PDA. 1.4.6 Recording The camera can be used with an iSCSI server connected via the network to store long-term recordings. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Clicking this icon stores the video sequences and they can be replayed with the Player from Bosch Security Systems included with the package. Bosch Security Systems Operating Instructions Introduction | en 19 V 2.5 | 2007.6...
20 en | Introduction 1.4.13 Intelligent Video Motion Detection The intelligent video motion detection (iVMD) system of the camera uses advanced analysis algorithms with comprehensive functions for the detection of motion. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
10mm A LA R M ET H Fig. 2.1 Power connection Bosch Security Systems - use a class 2 power supply - 24 VAC or 12 VDC - push in the tabs to open the quick-connectors (these connections are not polarity sensitive).
- connect a service monitor to the composite video BNC connector to aid installation. - a monitor connected close to the camera via this connection can also be used in parallel with remote PC viewing. Operating Instructions Dinion IP Bosch Security Systems...
Relay out contact 2 Alarm Pin 4 Pin 1 Fig. 2.4 Network and power connection Bosch Security Systems - Max. wire diameter AWG 22-28 for both stranded and solid. - Default relay position n.o. (normally open), no alarm. - Alarm output relay switching capability: Max voltage 30VAC or +40VDC.
The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections. V 2.5 | 2007.6 Bosch DC iris lens Damp - Damp + Drive + Drive - Operating Instructions Dinion IP Bosch Bosch Security Systems...
Do not obstruct the free flow of air around the camera. NOTE! The camera becomes quite warm when operating; this is normal. However, you should take this into account when touching the camera. Bosch Security Systems Operating Instructions Mounting | en 25 V 2.5 | 2007.6...
To adjust back focus: Open the slide door at the side of the camera Unlock the back focus locking button. Turn the back focus adjustment as required. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Press the menu/select key to access the menus or to move to the next or previous menu. – Press the menu/select key for approximately 1.5 seconds to open the Installer menu. Bosch Security Systems Up key Lock Down key Operating Instructions...
(Video iris lenses only). The level detector indica- tor must be set to the center by adjusting the level potentiometer on the lens, to obtain the best pic- ture performance. Return to the INSTALL menu Operating Instructions Dinion IP Bosch Security Systems...
The factory default IP address is 192.168.0.1 Function Selection IP Address Bosch Security Systems Description Enter an IP address for the camera. Use LEFT/RIGHT to change position in the address, use UP/DOWN to select the digit. Use SELECT to exit the address edit screen.
Only restore the factory defaults when it is absolutely necessary. V 2.5 | 2007.6 Enter the Subnet mask (default 255.255.255.0) Enter a Gateway address. Return to the Install menu Operating Instructions Dinion IP Bosch Security Systems...
192.168.0.1 Start the Web browser. Enter the IP address of the camera as the URL. Bosch Security Systems Insert the CD into the CD-ROM drive of the computer. If the CD does not start automatically, open the root directory of the CD in Windows Explorer and double click MPEGAx.exe.
Page 32
Depending on the device and network configuration, up to 20 web browsers, or 50 VIDOS or BVMS connections are supported. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Only after these have been configured can you communicate with the camera via the network. Bosch Security Systems Operating Instructions Network connection | en 33 V 2.5 | 2007.6...
6.1.1 Processor load When accessing the camera with a browser, the processor load is displayed in the upper right of the window next to the Bosch logo. Move the mouse cursor over the icons to display numerical val- ues. This information can help with problem solving or when fine tuning the device.
Individual images from the video sequence that is currently being shown on the Livepage can be saved in JPEG format on the computer's hard drive. Bosch Security Systems Operation via the browser | en 35 Operating Instructions V 2.5 | 2007.6...
Click the symbol for recording video sequences again. Sav- ing is terminated. Installing Player You can play back saved video sequences using the Player from Bosch Security Systems, which can be found on the software CD supplied. NOTE! A corresponding MPEG ActiveX (located on the CD provided with the product) must be installed on the computer in order to play back saved video sequences using the Player.
(see “Recording” on page 58). – Click Recordings in the navigation bar in the upper section of the window. The playback page appears. Bosch Security Systems Operation via the browser | en 37 Operating Instructions to indi-...
6.2.2 Controlling playback You will see a time bar below the video image for quick orienta- tion. If a particular sequence has been selected for playback by V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Page 39
You can use the slide control to control playback speed and fast forward/rewind: positioning in the middle indicates playback at Bosch Security Systems Operation via the browser | en 39 Operating Instructions V 2.5 | 2007.6...
Page 40
Bookmarks are only valid while you are in the Recordings page; they are not saved with the sequences. As soon as you leave the page all bookmarks are deleted. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Changes that influence the fun- damental functioning of the unit (for example firmware updates) can only be made using the configuration menu. Bosch Security Systems Configuration via the browser | en 41 Operating Instructions...
Page 42
Save the changes made in each window by clicking Set. Clicking the Set button saves only the settings in the current window. Changes in any other fields are ignored. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Camera ID Each camera should be assigned a unique identifier that can be entered here as an additional means of identification. Bosch Security Systems Configuration via the browser | en 43 Operating Instructions V 2.5 | 2007.6...
Service or if the unit is not pro- tected by a password. Enter the password for the selected user name here. Confirm password Re-enter the new password to rule out typing mistakes. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
This is added automatically. Enter the current time or click Synchr. PC to apply the sys- tem time from your computer to the camera. Bosch Security Systems Configuration via the browser | en 45 Operating Instructions V 2.5 | 2007.6...
If there are empty lines at the bottom of the table, for example after deletions, you can add new data by marking the row and selecting values from the list boxes. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
HyperTerminal, using the Custom option. Or it can be set to Off if no overlay of this information is to be shown. Bosch Security Systems Configuration via the browser | en 47 Operating Instructions...
You can adapt the MPEG-4 data transmission to the operating environment (for example network structure, bandwidth, data V 2.5 | 2007.6 If you have selected the Custom option, additional fields are displayed to specify the exact position (Position (XY):). Operating Instructions Dinion IP Bosch Security Systems...
Page 49
You will see a preview for each data stream in the right section of the window. The preview of the data stream currently selected is marked by a frame. Various additional items of infor- Bosch Security Systems Configuration via the browser | en 49 Operating Instructions...
Therefore it is generally best to use the default profiles. The profiles should only be changed if you are completely familiar with all the configuration options. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Page 51
1/2 D1 352 × 576/480 pixels – 2CIF 704 × 288/240 pixels – 4CIF/D1 704 × 576/480 pixels – 2/3 D1 464 × 576/480 pixels Bosch Security Systems Configuration via the browser | en 51 Operating Instructions V 2.5 | 2007.6...
Page 52
4 and 31 on a slide bar. The value 4 represents the best quality with, if necessary, a lower frame refresh rate depending on the settings for the maximum data V 2.5 | 2007.6 Operating Instructions Bosch Security Systems...
When setting this parameter, please ensure that the date and time of the unit are always correctly set. Example: the file snap021606_124530.jpg Bosch Security Systems Configuration via the browser | en 53 Operating Instructions V 2.5 | 2007.6...
Page 54
Check the box to activate one or more camera inputs for the JPEG image. An enabled camera input is indicated by a check mark. NOTE! The numbering follows the labeling of the video inputs on the actual unit. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
10K) as long as the light level of the scene permits. – FL - flickerless mode avoids interference from light sources (recommended for use with video iris or DC iris lenses only). Bosch Security Systems Configuration via the browser | en 55 Operating Instructions V 2.5 | 2007.6...
When ON, the video level is optimized for the center of the image. Parts outside this area may be underexposed or overex- posed (this is normal). Auto Black Autoblack ON automatically increases the visibility of details. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Offset factory white point alignment (reducing blue introduces more yellow). It is only necessary to change the white point offset for special scene conditions. Bosch Security Systems Configuration via the browser | en 57 Operating Instructions V 2.5 | 2007.6...
The VRM is an external program that configures recording tasks for video servers. For further information, con- tact your local customer service at Bosch Security Systems. V 2.5 | 2007.6 A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.
In this window, click Delete to delete all entries. Entries are deleted immediately; you cannot undo this process. Click Close to close the window. Bosch Security Systems Configuration via the browser | en 59 Operating Instructions V 2.5 | 2007.6...
Enter the IP address of the required iSCSI server here. Click Connect. The connection to the IP address is estab- lished. The iSCSI LUN map field contains the correspond- ing logical drives. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
If the drive is password protected, enter the password. NOTE! You may not enter a new password. This is only possible by configuring the iSCSI storage device. Bosch Security Systems Configuration via the browser | en 61 Operating Instructions V 2.5 | 2007.6...
Click Log to view a status report with logged actions. A new window opens. In this window, click Delete to delete all entries. Entries are deleted immediately; you cannot undo this process. Click Close to close the window. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Click Create partition to start the wizard for creating parti- tions. The first window appears. Bosch Security Systems Configuration via the browser | en 63 Operating Instructions V 2.5 | 2007.6...
Page 64
Finish button. CAUTION! All modifications to settings are only effective if you complete the configuration in the last window by clicking Finish. Switch to the last window if necessary. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Consequently, you should back up all important sequences on the computer's hard drive before modifying the partition. Bosch Security Systems A window opens showing information on the high- lighted partition. This window provides information about the current configuration of the partition. No changes can be made here.
Page 66
Alarm tracks must be set up for alarm recording. V 2.5 | 2007.6 A new window with the entries for the selected parti- tion is opened. You can modify the configuration in the Partition properties window. Operating Instructions Dinion IP Bosch Security Systems...
Page 67
Check the recordings before deleting and back-up important sequences on the computer's hard drive. – Click Format! to delete all recordings in the current parti- tion. Bosch Security Systems Configuration via the browser | en 67 Operating Instructions V 2.5 | 2007.6...
You can define up to ten separate recording profiles. You then assign these to individual days or times of day in the recording scheduler. Modify the names of the recording profiles on the tabs in the Recording planner page. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Page 69
The recording profile can deviate from the standard setting Active profile and is only used during an active recording. Encoder Select which data stream to record here. Bosch Security Systems Configuration via the browser | en 69 Operating Instructions V 2.5 | 2007.6...
Page 70
Select the encoder profile to use for recording during the post- alarm time. The Standard profile option sets this to the same as the standard profile. Motion detection/video alarm Select the alarm type that is to trigger a recording. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Use the right mouse button to deselect any of the intervals. Click Select all to select all of the intervals to be assigned to the selected profile. Bosch Security Systems Configuration via the browser | en 71 Operating Instructions V 2.5 | 2007.6...
Recording scheduler are deactivated and the configura- tion cannot be modified. You can terminate recording at any time to modify the configuration. Click Start to activate the recording schedule. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
You can enter a name for each alarm input, which is then dis- played below the icon for the alarm input on the Livepage dur- ing configuration. Bosch Security Systems Configuration via the browser | en 73 Operating Instructions V 2.5 | 2007.6...
If the remote location is password protected, enter the pass- word here. Only ten passwords can be defined here. You can define a gen- eral password if more than ten connections are required, for V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Page 75
NOTE! Stream 2 is always transmitted for automatic connections. This should be taken into account when assigning the profile. Bosch Security Systems Configuration via the browser | en 75 Operating Instructions V 2.5 | 2007.6...
If you select Motion+ analysis, for example, the sensor fields in which movement is registered light up. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
The current alarm status is displayed for information purposes. NOTE! Additional analysis algorithms with comprehensive functions such as IVMD are available from Bosch Security Systems. 7.12.3 Motion detector Motion detection is available for the Motion+ analysis type. For the detector to function, the following conditions must be met: –...
Click Select area to configure the sensor fields. A new win- dow opens. If necessary, click Clear all first to clear the current selec- tion (fields marked red). Left-click the fields to be activated. Activated fields are marked red. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Scene too bright Activate this function if tampering associated with exposure to extreme light (for instance, shining a flashlight directly on the Bosch Security Systems Configuration via the browser | en 79 Operating Instructions V 2.5 | 2007.6...
Page 80
You can activate or deactivate each of these fields indi- vidually. NOTE! Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit, as false alarms could otherwise be triggered. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Mail server IP address Enter the IP address of a mail server that operates on the SMTP standard (Simple Mail Transfer Protocol). Outgoing e-mails are Bosch Security Systems Configuration via the browser | en 81 Operating Instructions V 2.5 | 2007.6...
Test the e-mail function by clicking Send now. An alarm e-mail is immediately created and sent. 7.14 Relay Settings Here, you can make the settings for the alarm sources and alarm connections. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Trigger relay Click the button to switch the relay manually (for example for testing purposes or to operate a door opener). Bosch Security Systems Configuration via the browser | en 83 Operating Instructions V 2.5 | 2007.6...
Click Set after entering a new IP address. – V 2.5 | 2007.6 To do this, enter the old IP address followed by / reset (for instance 192.168.0.80/reset) in the address bar of your web browser. When the camera is Operating Instructions Dinion IP Bosch Security Systems...
Page 85
Also ensure that Java application support is activated (in the Java Plug-in Con- trol Panel of the Windows Control Panel). Bosch Security Systems restarted it can only be accessed at the new IP address.
Page 86
1. SNMP host address / 2. SNMP host address The camera supports the SNMP V2 (Simple Network Manage- ment Protocol) for managing and monitoring network compo- V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
VIDOS or BVMS, will not find the camera. 7.15.2 Multicasting In addition to a 1:1 connection between an encoder and a sin- gle receiver (unicast), the camera can enable multiple receivers Bosch Security Systems Configuration via the browser | en 87 Operating Instructions V 2.5 | 2007.6...
Page 88
The camera supports multi-unicast connections for up to five simultaneously connected receivers. NOTE! Duplication of data places a heavy demand on the CPU and can lead to impairment of the image quality under certain circumstances. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Click an entry to select it (select multiple entries by hold- ing the control key while clicking). Click Clear keys to delete the keys for the marked streams. These streams are no longer encrypted. Bosch Security Systems Configuration via the browser | en 89 Operating Instructions V 2.5 | 2007.6...
This window is for information only and cannot be modified. Keep this information at hand when seeking technical support. For example, you can copy the hardware and firmware version numbers to paste them into an e-mail. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Mark the check boxes for the information to be displayed on the Livepage. The selected elements are checked. Check on the Livepage whether and how the desired items are displayed. Bosch Security Systems Configuration via the browser | en 91 Operating Instructions V 2.5 | 2007.6...
Page 92
VCA are displayed in the live video stream. Show event log The event messages are displayed with the date and time in a field next to the video image. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
If necessary, click Search to find a suitable folder. 7.15.6 Licenses You can enter the activation key to release additional functions or software modules. Bosch Security Systems Configuration via the browser | en 93 Operating Instructions V 2.5 | 2007.6...
The latest firmware can be obtained from your customer service center or from the Bosch Security Systems download area. V 2.5 | 2007.6 Operating Instructions Dinion IP...
Page 95
Click Download; a dialog box appears. Follow the instructions to save the current settings. Bosch Security Systems Configuration via the browser | en 95 Operating Instructions V 2.5 | 2007.6...
– Does the camera transmit all the data required? – Does the camera respond as desired to alarm events? – Is it possible to control peripheral devices if necessary? V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
In this case, no computer is needed to establish the connection. Bosch Security Systems Connections between video servers | en 97 Operating Instructions V 2.5 | 2007.6...
In the title bar of the Monitor window on the page Connec- tions, click the X icon to end the display of the video images on the connected monitor. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
IP video security solution that provides seamless management of digital video, audio and data across any IP net- work. It is designed to work with Bosch CCTV products as part of a total video security management system. Now you can inte- grate your existing components into one easy-to-manage sys- tem, or use Bosch’s full-line capabilities and benefit from a...
Defective or superfluous devices and parts should be disposed of profes- sionally or taken to your local collection point for hazardous materials. V 2.5 | 2007.6 Operating Instructions Dinion IP Bosch Security Systems...
Dinion IP Troubleshooting If you cannot resolve a fault, please contact your supplier or system integrator or go direct to Bosch Security Systems Cus- tomer Service. The version numbers of the internal processors can be viewed on a special page. Please note this information before contact- ing Customer Service.
Page 102
Check iSCSI server configuration and reconnect. Check iSCSI server configuration and reconnect. Delete the identity on the iSCSI- parameter configuration page. Operating Instructions Dinion IP Solution Alarm sources configuration Alarm connec- configuration page, if neces- Bosch Security Systems...
ICMP IEEE IGMP Internet Protocol Bosch Security Systems IEEE 802.3 specification for 10 or 100 MBit/s Ethernet The IEEE standard, 802.1x, provides a general method of access control and authorization for IEEE 802-based net- works. An authenticator provides authentication by access-...
Page 108
RADIUS is the de-facto standard for centralized authentication of dial-ins for modems, ISDN, VPN, wireless LAN (see 802.1x), and DSL. A protocol for synchronizing computer clocks over the Inter- Operating Instructions Dinion IP Bosch Security Systems...
Page 109
Dinion IP RS232/RS422/RS485 SNTP Subnet mask Telnet Wide area network Bosch Security Systems Standards for serial data transmission Realtime Transport Protocol; A transmission protocol for real-time video and audio Simple Network Time Protocol is a simplified version of NTP (see NTP).