Mitsubishi Electric MELDAS C6 Programming Manual page 146

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

SFT input
SFT command
SFTP command
Program example
(1) Program to shift the data of Y57 to Y5B when X8 turns ON.
X8
6
M0
9
(pules coding)
X7
23
M8
25
M0
X7
Y57
Y58
Y59
Y5A
Y5B
7. Basic Commands
SFT, SFTP
ON
OFF
Executed per scan
PLS M0
SFT
Y5B
SFT
Y5A
SFT
Y59
SFT
Y58
PLS M8
SET Y57
- 137 -
Get other manuals https://www.bkmanuals.com
Executed per scan
Shifting is executed when M0 turns ON.
(program from the largest device No.)
X57 is turned ON when X7 turns ON.
Coding
No. of
Com-
steps
mand
6
LD
7
PLS
9
LD
10
SFT
13
SFT
16
SFT
19
SFT
22
LD
23
PLS
25
LD
26
SET
27
Device
X8
M0
M0
Y5B
Y5A
Y59
Y58
X7
M8
M8
Y57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64

Table of Contents