10.4 DDB (Direct Data Bus) ... Asynchronous DDB
The DDB function is used for PLC to directly read/write various pieces of data that controller has. PLC
can read specified data into buffer or write specified data into controller by storing necessary
information for read/write and calling the DDB function. Generally, data is read or written for each
data piece; data concerning the control axes is processed in batch as many as the specified number
of axes.

10.4.1 Basic Format of Command

(Note 1) File registers (Rn) and data registers (Dn) to which the user is accessible can be used as
the asynchronous DDB control data buffer. The file registers (R) to which the user is
accessible are R4000 through R4499 (not backed up) and R6400 through R7199 (backed
up).

10.4.2 Basic Format of Control Data

Rn(Dn)
Rn+1(Dn+1)
Rn+2(Dn+2)
Rn+4(Dn+4)
Rn+5(Dn+5)
Rn+6(Dn+6)
Rn+8(Dn+8)
Rn+10(Dn+10)
Rn+12(Dn+12)
~ ~
10. Exclusive Commands 2

10.4 DDB (Direct Data Bus)

Control data is set by using MOV command, etc.
ACT
Control signal
Large section No.
Sub section No.
Data size
Read/write designated axis,
part system designation
Read/write data
(For 1st axis)
(For 2nd axis)
(For 3rd axis)
(For 4th axis)
- 371 -
Get other manuals https://www.bkmanuals.com
(Note 1)
S.DDBA
Rn/Dn
(Note 1) Part system designation is used
for multi-part system specifications.
(Note 2) If only the 3rd axis is designated
for example, the section for the
3rd axis will be read/write data.
~ ~