Program example
(1) Program to reset 100ms cumulative timer and counter.
X4
10
T96
14
C23
20
X5
22
2 steps are used for T or C device.
1 step is used for the other devices.
7. Basic Commands
RST
T96 K18000
C23
K16
RST
T96
Y55
RST
C23
- 129 -
Get other manuals https://www.bkmanuals.com
When T96 is set for the cumulative timer,
T96 will turn ON when the X4 ON time is 30 min.
The No. of times that T96 turns ON is counted.
T96 is reset when T96 turns ON.
Y55 turns ON when C23 counts up.
C23 is reset when X5 turns ON.
Coding
No. of
Com-
steps
mand
10
LD
X4
11
OUT
T96
14
LD
T96
15
OUT
C23
18
RST
T96
20
LD
C23
21
OUT
Y55
22
LD
X5
23
RST
C23
25
Device
K18000
K16