Setting Options / Control; Monoblock Devices - ABB Busch E-contact System Manual

Table of Contents

Advertisement

2.3

Setting options / control

2.3.1

Monoblock devices

Depending on the device, the following methods for setting or configuration are available.
Extension units are not set. The main unit is used for control.
Trimmers
time
30
15
A
5
1
1
5
HA
15
30
Fig. 6:
Setting via trimmers
The trimmers for setting devices are located below the device cover.
Settings of trimmer right
System Manual 2CKA001473B9577
Lux
5
50
min
T
300
min
1.000
2.000
Setting of brightness-value threshold
The sensor switches the light on only when the measured brightness value is
below the value set on the trimmer (5 to 2,000 lux).
When movement is detected, the sensor switches the light on with the set
switch-off delay. The switch-off delay is started anew at every detected
movement.
Setting of daylight
The brightness sensor is ignored at setting of daylight.
The sensor switches the light on by itself exclusively depending on movement.
Setting of test mode
At setting of test mode the switch-off delay amounts to approx. 5 seconds and
the brightness value is set on daylight operation. The detection range can be
checked in test mode.
The test LED flashes at every detected movement and the connected load
switches on for approx. 5 seconds.
To end the test mode, set the desired brightness-value threshold on the device
or press the desired brightness-value threshold on the IR remote control (not
possible with Sky sensors 64754-xxx) due to the large mounting height.