    Table of contents Introduction Principle of operation 5–12 System – Surveillance Areas 13–14 Special features of the 15–19 Busch Watchdog Professional/Alarmtech Interference factors 20–21 Fields of application 22–23 Installation 24–27 Product features/product overview 28–31 Busch Watchdog range 32–35 Examples of typical circuits 36–43 Troubleshooting 44–46...
  • Page 2: Introduction

    Introduction Principle of operation A reliable infrared movement • The Busch Watchdog is detector offers additional purely a receiver and trans- protection. It ensures that mits no signals itself. The nobody can enter its surveil- connection between the lance zone without activating heat source and the Busch the lights.
  • Page 3: Busch Watchdog Professional/Alarmtech

    Principle of operation The detection principle Wall-mounted Ceiling-mounted Busch Watchdog Busch Watchdog All bodies with internal heat Professional/Alarmtech Professional/Alarmtech emit infrared radiation. The sensors used in the Busch Watchdog can detect this infrared radiation. The more distinct the radiation in rela- tion to the surrounding area, i.e.
  • Page 4 Principle of operation Connection and settings • Sensitivity (E) The delay time of three The Busch Watchdog has minutes and the light level The watchdog is connected three sensitivity level of 4 lux are fixed. with the wall-mounted bracket settings. The standard level •...
  • Page 5 Principle of operation • The masking strips The lens system of the With the masking strips, Busch Watchdog, which is areas that are not to be permanently connected to monitored can be specif- the sensor housing to provide ically excluded from the a good seal for the unit, has surveillance zone.
  • Page 6 Principle of operation System 220° 90° The microprocessor • Short-time pulse, e.g. for The detection angle staircase timer switch The use of a microprocessor Additional protection for to control the Busch • Precise digital time and windows and doors up to the Watchdog provides a series dusk setting wall of the house, even in...
  • Page 7 Levels 1 and 2 cover remote surveillance and ensure seamless detection when the Busch Watchdog Professional 220 surveillance zone is entered Busch Watchdog Professional 220 EIB from the outside. Rearfield detection Rearfield detection Range up to 16 m Range up to 12 m Detection zone approx.
  • Page 8 Special features of the Busch Watchdog Alarmtech 220 Alarm function Remote control Rearfield detection The security provided by the The main functions can be Security zone up to 6 m Busch Watchdog Alarmtech controlled with a hand-held Range up to 16 m 220 is unsurpassed.
  • Page 9 Special features of the Busch Watchdog Professional 220/280 and Busch Watchdog Alarmtech 220 To avoid this situation and settings, select the desired If, for example, the detector therefore increase security, delay time and the dusk value switches on due to sunlight, the Busch Watchdog leaves to complete the installation.
  • Page 10: Interference Factors

    Interference factors Inadvertent operation nearby) or animals in the Range fluctuations The automatic range stabil- detection zone can also isation of the Busch The principle of operation of trigger detection. In extreme weather condi- Watchdog counteracts the a passive infrared movement tions, the size of the detec- effects described above, but, detector means that its func-...
  • Page 11 Applications This table lists only some Busch Watchdog Busch Watchdog Busch Watchdog Busch Watchdog of the many possible devices Professional 220/ Alarmtech 220 180 UP applications. 90/280/220 EIB Comfort II Standard/Comfort II You will also find the appropriate version for your specific application.
  • Page 12: Installation

    Installation as a movement of a heat line of vision of the Busch Spotlights should not be source in the surveillance Watchdog. aimed directly at the Busch zone. Watchdog. 4. Every passive infrared 2. When specifying the movement detector 6.The range to the front can 2.5 m mounting location and responds to a fast change...
  • Page 13 7. The adjustment screws 9. Ceiling installation 10. Installation in lighting must always point down- The Busch Watchdog control systems wards after installation, Professional and Alarmtech The detection zone must otherwise the direction of units are ideally suited for be adapted to the local detection is upwards.
  • Page 14 Busch Watchdog AP Professional Professional Professional Professional Alarmtech 220 EIB Angular detection coverage 90° 220° 220° > 280° 220° Surveillance levels Range, frontal (max.) 12 m 16 m 16 m 16 m 16 m Range, to sides (max.) 16 m 16 m 16 m 16 m...
  • Page 15 The Busch Watchdog flush mounting range Comfort II * 6800-2X-104 6800-2X-104M *Switch-off behaviour: In combination with 6593 U (soft Off function), the Komfort II sensor dims down and switches off within 60 seconds. 2020 US 6402 U 6805 U 6401 U-10x 6812 U-101 6804 U-10x 6593 U...
  • Page 16: Busch Watchdog Range

    Busch Watchdog range UP devices/presence indicators AP devices Busch Watchdog Busch Watchdog Busch Watchdog Busch Watchdog Professional 220/220 EIB Professional 90 Comfort II Presence Detector Busch Watchdog Busch Watchdog Professional 280 Alarmtech 220 Please ask for revised user manual.
  • Page 17 Special equipment/accessories RC element Surface mounting enclosure for Busch Watchdog Corner adapter Presence Detector...
  • Page 18 Typical circuits for AP Last z. B. Beleuchtung Load, e.g. illumination oder Signalgeber or signal transmitter ® Taster/Öffner Push Switch Busch Watchdog Alarmtech 220 Busch-Wächter Leuchte Lamp (Push to break) Alarmtech 220 Two-way switch Busch Watchdog Lamp Busch Watchdog Alarmtech 220 switched on through a push switch. If the Changeover through two-way switch to PERMANENTLY ON or Busch power supply of the Busch Watchdog Alarmtech 220 is intermittently Watchdog mode.
  • Page 19 Typical circuits for AP Two-way switch Busch Watchdog Lamp Push Switch Busch Watchdog Lamp Combination of an existing two-way circuit with a Busch Watchdog. Two-way Parallel operation of several Busch Watchdogs, for example in conjunction with circuit and Busch Watchdog have the same priority. a push switch for several sides of the house RC fuse Art.
  • Page 20 Typical circuits for AP RC fuse Art. No. 6899 Push Switch Busch Watchdog Lamp Busch Watchdog Time/flasher relay Lamp (Push to break) Busch Watchdog switched on through a push switch. If the power supply of Extension of the Off delay or actuation of a pulse relay (e.g. for flashing lights) the Busch Watchdog is intermittently interrupted in standby mode and then reconnected, the lights are switched on automatically for the set delay time.
  • Page 21: Examples Of Typical Circuits

    Examples of circuits, UP Push Switch Busch Watchdog Push Switch 6805 U 6804 U (Push to break) (Push to make) Activating the Busch Watchdog UP 180/6812 U, Standard or Comfort 6401 U-10x, 6804 U/6593 U with push switches. When the power to the Busch Actuation of a light with Busch Watchdog 180 UP Comfort 6401 U-10x, Watchdog is briefly interrupted by the switch, it is automatically activated for 6804 U or 6593 U in conjunction with the Busch Watchdog 6805 U slave...
  • Page 22: Troubleshooting

    Troubleshooting Fault Possible cause/remedy Fault Possible cause/remedy Light does not come on - Connect supply voltage, Automatic undesired - Switch-on after power check mains voltage switching failure; wait - Lens obscured; clean lens - Sunlight or heat reflection; or remove masking strip readjust area detection or use shutter - No detection;...
  • Page 23 Notes Fault Possible cause/remedy Watchdog does not - Watchdog is operating in respond to changes dazzleproof mode; normal at the dusk sensor...