Abb Flextronics - ABB Busch E-contact System Manual

Table of Contents

Advertisement

3.5.2

ABB flexTronics

Fig. 12: Display of operating status
The operating status of the devices is displayed by means of a red LED at the front of the
device.
Devices with IR reception
Operating status
Test mode
Continuous light operation
Continuous OFF operation
Manual mode
Automatic mode
IR reception
Table 20:Operating status: Busch-Presence detector flex sensors
System Manual 2CKA001473B9577
®
LED
Flashes at a detected movement, the connected load switches
on for approx. 5 seconds.
In test mode the switch-off delay amounts to 5 seconds, the
brightness value is set on daylight.
Switch the test mode by setting the desired brightness value on
the trimmer or by pressing the desired switch-off delay on the IR
remote control (not possible with 64754-xxx)
Notice
Due to the high sensitivity in the internal detection range (directly
below the device), the pacing of the detection range is only possible
with a distance of more than 2 metres from the device. If you are
within this detection range, the device will always detect movement
and not switch off.
Continuous ON
Continuous ON
OFF
OFF
Flashes fast