5.4. Operating and Storage Temperatures

Table 41: Operating and Storage Temperatures
Parameter
Operating temperature Range
Extended Temperature Range
Storage temperature Range

5.5. Power Consumption

Table 42: EM160R-GL Power Consumption
Mode
Condition
OFF state
Power off
AT+CFUN=0
WCDMA PF = 64
WCDMA PF = 128
Sleep State
WCDMA PF = 256
WCDMA PF = 512
LTE-FDD PF = 32
LTE-FDD PF = 64
13
To meet the normal operating temperature range requirements, it is necessary to ensure effective thermal dissipation,
e.g., by adding passive or active heat sinks, heat pipes, vapor chambers. Within the temperature range of -10 ° C to +55 ° C,
the mentioned RF performance margins higher than 3GPP specifications can be guaranteed. When temperature goes
beyond temperature range of -10 ° C to 55 ° C, a few RF performances of module may be slightly off 3GPP specifications.
14
To meet the extended operating temperature range requirements, it is necessary to ensure effective thermal dissipation,
e.g., by adding passive or active heat sinks, heat pipes, vapor chambers. Within this range, the module remains the ability
to establish and maintain functions such as SMS, without any unrecoverable malfunction. Radio spectrum and radio
network are not influenced, while one or more specifications, such as P
specified tolerances of 3GPP. When the temperature returns to the normal operating temperature level, the module will
meet 3GPP specifications again.
EM160R-GL_Hardware_Design
Min.
Typ.
13
-25
+25
14
-40
-
-40
-
LTE-A Module Series
Max.
+75
+85
+90
Typ.
54
1.55
2.81
2.34
2.03
1.91
4.97
5.48
, may undergo a reduction in value, exceeding the
out
Unit
º C
º C
º C
Unit
μA
mA
mA
mA
mA
mA
mA
mA
61 / 73