Installation; General - Hatco CWBP Series Installation And Operating Manual

Refrigerated drop-in wells
Table of Contents

Advertisement

Available languages

Available languages

English

General

Refrigerated Drop-In Wells are shipped from the factory
completely assembled and ready for use. Use the following
information and procedures to prepare the unit and installation
site.
EXPLOSION HAZARD:
• Do NOT puncture refrigerant tubing. Use extreme
caution and follow all local/regional codes for
transportation or relocation of hydrocarbon equipment.
• Do NOT move or rotate condensing unit. Damage to
refrigerant tubing will occur.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this equipment.
• Smoking is strictly prohibited near equipment with
R-290 (hydrocarbon) refrigerant.
This unit uses flammable refrigerant. Follow handling
instructions carefully in compliance with US and/or
Canadian government regulations.
This unit must be installed in an isolated and sealed
cabinet/partition only.
Do NOT use electrical appliances inside of the food storage
compartments or inside the cabinet under the unit.
Do NOT use mechanical devices or any other means to
accelerate the defrosting process. Follow the "Setting the
Auto-Defrost Cycle" procedure in the OPERATION section
in this manual to defrost ice buildup.
Keep all ventilation openings clear of obstructions at all
times.
WARNING
ELECTRIC SHOCK HAZARD:
• Plug unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. If
plug and receptacle do not match, contact a qualified
electrician to determine and install proper voltage and
size electrical receptacle.
• Unit is not weatherproof. Locate unit indoors.
FIRE HAZARD:
• Install unit with a minimum of 7" (178 mm) of space
between all sides of condensing unit and any
combustible surfaces.
• Provide louvered or grill-style openings with a size of
12" x 12"/144 square inches (31 x 31 cm/961 square cm)
in the cabinetry in front of and behind the condensing
unit for proper ventilation. Failure to provide adequate
air flow through the condensing unit may cause fire
and/or unit failure and will void the unit warranty.
• All electrical receptacles must be at least 12" (305 mm)
above the cabinet floor.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Check with local plumbing and electrical
inspectors for proper procedures and codes.
CWBPM-0923
DANGER
Locate unit at the proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.
Transport and install unit in upright position only. Failure
to do so may result in damage to refrigeration system.
This unit is designed for use in environments where
ambient temperature is between 65°F (18°C) and 86°F
(30°C).
For proper operation this unit must be installed with intake
ducting. Failure to install properly will void warranty.
When shipped during cold weather months, store unit in
proper ambient temperature environment for 10 hours to
prevent compressor and/or refrigerant line damage. If unit
is turned on and there is excessive noise and vibration,
turn off immediately and allow additional warm up time.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
All Refrigerated Drop-In Wells are shipped in a shipping frame
for protection and stability. Keep the unit in the shipping frame
until the unit and the installation site are completely prepared
for the unit to be installed.
1. Remove all external packaging from the unit.
2. Remove tape, protective packaging, and literature from all
surfaces of the unit.
NOTE: To prevent delay in obtaining warranty coverage, complete
online warranty registration. See the IMPORTANT
OWNER INFORMATION section for details.
7

INSTALLATION

CAUTION
NOTICE