Summary of Contents for Hatco FLAV-R-SAVOR FSHC-6W Series
Page 1
All manuals and user guides at all-guides.com FLAV-R-SAVOR ® Portable Holding Cabinets FSHC-6W and FSHC-7 Series Installation and Operating Manual I&W #07.05.152.00 Este manual contiene importante información sobre This manual contains important safety information concerning the maintenance, use and operation of this seguridad concerniente al mantenimiento, uso y product.
® (Summer Hours: June to September – the spaces provided. Please have this information 8:00 a.m. to 5:00 p.m. C.D.T. available when calling Hatco for service assistance. Monday through Thursday 8:00 a.m. to 2:30 p.m. C.D.T. Friday) Model No. ________________________________ Telephone: (800) 558-0607;...
Hatco equipment. It To prevent any injury or damage to the unit do is essential to use Hatco Replacement Parts not pull unit by power cord.
Page 4
All manuals and user guides at all-guides.com IMPORTANT SAFETY INFORMATION CAUTIONS NOTICES To avoid any injury or damage locate the Water Quality Requirements - Incoming water in Holding Cabinet at the proper counter height, excess of 3.0 grains of hardness per gallon in an area that is convenient for use.
All manuals and user guides at all-guides.com MODEL DESCRIPTION ALL MODELS Flav-R-Savor Portable Holding Cabinets are made ® of sturdy stainless steel and powdercoat painted top, sides back. Features include thermostatically controlled heat and humidity, a digital temperature readout and a large aluminum framed tempered glass door or insulated stainless steel door.
All manuals and user guides at all-guides.com SPECIFICATIONS ELECTRICAL RATING CHART Model Voltage Hertz Watts Amps Plug Configuration Shipping Weight FSHC-6W-1 1697 14.1 NEMA 5-15P* 175 lbs. (79 kg) 1697 CEE 7/7 Schuko 175 lbs. (79 kg) 1697 BS-1363 175 lbs. (79 kg) 1697 AS-3112 175 lbs.
All manuals and user guides at all-guides.com SPECIFICATIONS DIMENSIONS Width Depth Height† FSHC-6W-2 Only Model FSHC-6W-1 25-3/8" 29-1/2" 32-1/8" (645 mm) (749 mm) (816 mm) FSHC-6W-2 25-3/8" 32" 32-1/8" (645 mm) (813 mm) (816 mm) Top Surface: 25-3/8"W x 25-7/8"D (645 x 657 mm) Cabinet Opening: 20-7/8"W x 19"H (530 x 483 mm) FSHC-6W Series Width...
All manuals and user guides at all-guides.com INSTALLATION ALL MODELS 5. Carefully lay the unit on its side. Thread one leg The Flav-R-Savor Portable Holding Cabinets are ® or mount caster using hardware provided onto shipped with most components installed and ready for operation.
All manuals and user guides at all-guides.com INSTALLATION LOCATION NOTE: The unit must be transported in the upright position. If laid on its side, water must be drained from the unit. See DRAINING THE RESERVOIR in the MAINTENANCE section. Screw WARNING For safe and proper operation, the unit must be located a minimum of 1"...
Page 10
All manuals and user guides at all-guides.com INSTALLATION Stainless Steel Door Strike Plate (Optional on FSHC-6W Series Only) The optional stainless steel door is not available for retrofit. Chrome Handle 1. Slide hinge covers off of edgemount hinges. (See Figure 6.) NOTE: Hinges remain mounted to the stainless steel door.
Add water to the reservoir until the alarm shuts off. buildup is not covered under warranty. WARNING NOTICE Hatco corporation is not responsible for the Do not use deionized water. Deionized water will actual food product serving temperature. It is greatly shorten the life of the water reservoir and the responsibility of the user to assure that the water heating element.
All manuals and user guides at all-guides.com OPERATION FOOD HOLDING GUIDE Maximum Humidity Temperature Type of Food Holding Time Setting Setting °F °C Bagels 3 Hours Biscuits 2 Hours Medium Chicken - Parts 5 Hours High Chicken - Whole 2 Hours High Croissants 3 Hours...
All manuals and user guides at all-guides.com MAINTENANCE GENERAL Hatco Flav-R-Savor Portable Holding Cabinets are ® designed for maximum durability and performance, with minimum maintenance. WARNING To avoid any injury, turn the power switch OFF, unplug the unit from the power source and allow to cool completely before performing any maintenance or cleaning.
Hatco equipment. It is essential to use 1. Turn the power switch off and unplug the unit Hatco Replacement Parts when repairing Hatco from its power source.
All manuals and user guides at all-guides.com ACCESSORIES STACKING KIT A special stacking bracket is available for stacking one FSHC-7 unit on top of another FSHC-7 unit or one FSHC-6W unit on top of another FSHC-6W unit. The stacking hardware secures the top unit to the bottom unit.
Move Power On/Off switch to the on not power on. position. Contact Authorized Service Agent or Power On/Off switch defective. Hatco for assistance. Electrical receptacle is defective. Check outlet and verify power supply matches specification tag on unit. Check circuit breaker and reset if Tripped circuit breaker.
(metal sheathed) referred to above. Hatco reserves the right to accept or reject any such claim in whole or in part. Hatco will b) One (1) Year Parts and Labor PLUS Four not accept the return of any Product without prior...
Page 18
All manuals and user guides at all-guides.com NOTES Form No. FSHC67M-0808...
Page 19
All manuals and user guides at all-guides.com NOTES Form No. FSHC67M-0808...
All manuals and user guides at all-guides.com HATCO AUTHORIZED PARTS DISTRIBUTORS ALABAMA IOWA NEW YORK TEXAS Jones McLeod Appl. Svc. Electric Motor Service Co. Acme American Repairs, Inc. GCS Service Birmingham 205-251-0159 Davenport 319-323-1823 Brooklyn 718-456-6544 Fort Worth 800-433-1804 Goodwin Tucker Group Alpro Service Co.
Need help?
Do you have a question about the FLAV-R-SAVOR FSHC-6W Series and is the answer not in the manual?
Questions and answers