Installation; General - Hatco CWBP-S Series Installation And Operating Manual

Slim refrigerated drop-in wells
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

General

Refrigerated Slim Drop-In Wells are shipped from the factory
completely assembled and ready for use. Use the following
information and procedures to prepare the unit and installation site.
EXPLOSION HAZARD:
• Do NOT puncture refrigerant tubing. Use extreme
caution and follow all local/regional codes for
transportation or relocation of Hydrocarbon equipment.
• Do NOT move or rotate condensing unit. Damage to
refrigerant tubing will occur.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this equipment.
• Smoking is strictly prohibited near equipment with
R-290 refrigerant.
This unit uses flammable refrigerant. Follow handling
instructions carefully in compliance with US and/or
Canadian government regulations.
This unit must be installed in an isolated and sealed
cabinet/partition only.
Do NOT use electrical appliances inside of the food storage
compartments or inside the cabinet under the unit.
Do NOT use mechanical devices or any other means to
accelerate the defrosting process. Follow the "Setting the
Auto-Defrost Cycle" procedure in the OPERATION section
in this manual to defrost ice buildup.
Keep the ventilation openings clear of obstructions at all
times.
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
Cut out exhaust opening in
one of the white highlighted
areas when installing well
and condensing unit in this
orientation.
Countertop removed
for clarity.
DANGER
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors.
FIRE HAZARD:
• Install unit with a minimum of 7" (178 mm) of space
between all sides of condensing unit and any
combustible surfaces.
• Provide louvered or grill-style openings with a minimum
size of 12" x 12"/144 square inches (31 x 31 cm/
961 square cm) in the cabinetry in front of and behind
the condensing unit for proper ventilation. Failure to
provide adequate air flow through the condensing unit
may cause unit failure and will void the unit warranty.
• All electrical receptacles must be at least 12" (305 mm)
above the cabinet floor.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Check with local plumbing and electrical
inspectors for proper procedures and codes.
Locate unit at the proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.
Transport and install unit in upright position only. Failure
to do so may result in damage to refrigeration system.
This unit is designed for use in environments where
ambient temperature is between 65°F (18°C) and 86°F
(30°C).
For proper operation this unit must be installed with intake
ducting. Failure to install properly will void warranty.
Cut out the intake opening in one
Condenser Coils
of the gray highlighted areas when
(inside duct collar)
installing well and condensing unit
in this orientation.
Countertop Cutout
8
English
WARNING
CAUTION
NOTICE
12" x 12"
cutout for
intake air.
CWBPSM-0923

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cwbp-s1Cwbp-s2Cwbp-s3Cwbp-s4

Table of Contents