General

Built-In Heated Well units are shipped from the factory with
most components assembled and ready for use. Use the
following procedures to install the unit.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 21°C (70°F).
FIRE HAZARD:
• Install unit with a minimum of 89 mm (3-1/2"( of space
from bottom of unit to all combustible surfaces to
prevent combustion.
• Unit must be installed using ribbon putty gasket
between the unit and the installation surface per
installation instructions.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Check with local plumbing and electrical
inspectors for proper procedures and codes.
Locate the unit at the proper counter height in an area
that is convenient for use. The location should be strong
enough to support the weight of the unit and contents.
NOTICE
Units are voltage-specific. Refer to specification label for
electrical requirements before beginning installation.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
Unit is designed and recommended for use in or on
metallic countertops. Damage to any countertop material
is not covered under the Hatco warranty. For other
surfaces, verify with manufacturer that material is suitable
for prolonged temperatures up to 93°C (200°F).
Form No. HWB_SAM-0915
CAUTION
Remote mounted control panels must have a minimum
152 mm (6"( clearance from unit (not to exceed 1829 mm
[72"](. Mounting control panel closer may cause heat
damage to electrical system in control panel.
Damage to any countertop material caused by heat
generated from Hatco equipment is not covered under
the Hatco warranty. Contact the manufacturer of the
countertop material for application information.
NOTE: All Built-In Heated Wells require the control enclosure
be remote mounted in the vertical position.
1. Remove the unit from the box.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces
of unit.
NOTE: A qualified electrician is recommended for connecting
the Built-In Heated Well units to a power source. A
qualified plumber is recommended for connecting
drain.
3. Install the unit in the desired location. Use the appropriate
procedure in this section for combustible or non-
combustible countertops.
IMPORTANT NOTE:
For bottom mount units, see "Installing a Bottom Mount
Unit" in this section or "Mounting Bracket for Bottom Mount
Units" in the OPTIONS AND ACCESSORIES section before
performing any countertop cutouts.
4. Install the remote control enclosure (refer to the procedure
in this section).
11

INSTALLATION