Dimensions; Installation; General - Hatco FTBP-S Series Installation And Operating Manual

Drop-in frost top shelves
Table of Contents

Advertisement

Available languages

Available languages

English
Dimensions — FTBP Models
Width
Model
(A)
21-1/16"
FTBP-3/4
(535 mm)
(457 mm)
21-1/16"
28-15/16"
FTBP-1
(535 mm)
(735 mm)
39"
28-15/16"
FTBP-2
(991 mm)
(735 mm)
57"
28-15/16"
FTBP-3
(1448 mm)
(735 mm)

General

Drop-In Frost Top Shelves are shipped from the factory
completely assembled and ready for use. Use the following
information and procedures to prepare the unit and installation
site as well as to install the unit.
EXPLOSION HAZARD:
• Do NOT puncture refrigerant tubing. Use extreme
caution and follow all local/regional codes for
transportation or relocation of Hydrocarbon equipment.
• Do NOT move or rotate condensing unit. Damage to
refrigerant tubing will occur.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this equipment.
• Smoking is strictly prohibited near equipment with
R-290 (hydrocarbon) refrigerant.
This unit uses flammable refrigerant. Follow handling
instructions carefully in compliance with US and/or
Canadian government regulations.
This unit must be installed in an isolated and sealed
cabinet/partition only.
Do NOT use electrical appliances inside of the food storage
compartments or inside the cabinet under the unit.
Do NOT use mechanical devices or any other means to
accelerate the defrosting process. Follow the "Setting the
Auto-Defrost Cycle" procedure in the OPERATION section
in this manual to defrost ice buildup.
FTBPM-0923
Depth
Overall
Enclosure
(B)
Height (C)
Height (D)
18"
23-11/16"
3-9/16"
(601 mm)
(90 mm)
23-11/16"
3-9/16"
(601 mm)
(90 mm)
17-1/8"
3-9/16"
(434 mm)
(90 mm)
17-1/8"
3-9/16"
(434 mm)
(90 mm)
A
Front View
DANGER
Dimensions — FTBP-S Models
Width
Model
(A)
54-15/16"
FTBP-S2
(1395 mm)
80-13/16"
FTBP-S3
(2053 mm)
Keep the ventilation openings clear of obstructions at all times.
ELECTRIC SHOCK HAZARD:
• Plug unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. If
plug and receptacle do not match, contact a qualified
electrician to determine and install proper voltage and
size electrical receptacle.
• Unit is not weatherproof. Locate unit indoors.
FIRE HAZARD:
• Install unit with a minimum of 7" (178 mm) of space
between all sides of condensing unit and any
combustible surfaces.
• Provide louvered or grill-style openings with a size of
12" x 12"/144 square inches (31 x 31 cm/961 square cm)
in the cabinetry in front of and behind the condensing
unit for proper ventilation. Failure to provide adequate
air flow through the condensing unit may cause fire
and/or unit failure and will void the unit warranty.
• All electrical receptacles must be at least 12" (305 mm)
above the cabinet floor.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Check with local plumbing and electrical
inspectors for proper procedures and codes.
7
SPECIFICATIONS
Depth
Overall
(B)
Height (C)
21-1/16"
17-1/8"
(535 mm)
(434 mm)
21-1/16"
17-1/8"
(535 mm)
(434 mm)
B
D
Side View

INSTALLATION

DANGER
WARNING
Enclosure
Height (D)
3-9/16"
(90 mm)
3-9/16"
(90 mm)
C