General

Hatco Flav-R-Savor
Display Cabinets are shipped with most
®
components pre-assembled. Care should be taken when
unpacking shipping carton to avoid damage to the unit and
components enclosed.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 70°F (21°C).
FIRE HAZARD: Locate unit a minimum of 1" (25 mm) from
combustible walls and materials. If safe distances are not
maintained, discoloration or combustion could occur.
Transport unit in upright position only. Before moving or
tipping unit, secure all glass surfaces, doors, pan rails,
and/or skirts with tape, and drain water from humidified
units. Failure to do so may result in damage and injury.
The National Sanitation Foundation (NSF) requires that
units over 36" (914 mm) in width or weighing more than
80 lbs. (36 kg) either be sealed to or raised above the
installation surface. If unit cannot be sealed at the point of
use, accessory 4" (102 mm) legs are available to allow for
proper cleaning access below unit.
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces
of unit.
3. Install the door handles using the supplied handle screws.
4. Place the unit in the desired location.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F (21°C).
Avoid areas that may be subject to active air movements
or currents (i.e., exterior doors, exhaust fans/hoods, and
air conditioning ducts).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
• Make sure all the feet/legs on the bottom of the unit are
positioned securely on the countertop.
NOTE: Unit must be transported in the upright position.
FSM-1022
CAUTION

Reversing the Access Door

The Flav-R-Savor access door(s) may be hinged on either
the left or right side for convenience. The unit is shipped
standard with the door hinged on the left side. Use the following
procedure to reverse the access door to the right side.
1. Remove the screws and washers holding the door to the
hinges.
2. Remove the screws holding the hinges to the left side of
the cabinet.
3. Remove the screw plugs from the right side of the cabinet
and insert them into the holes on the left side.
4. Rotate the door 180°, and remount it on the right side of the
cabinet using the hinges and screws previously removed.
NOTE: The nylon washers must be reinstalled between the
door and the hinges.
Door
Hinge
Door Hinge
Screw
Reversing the Access Door
7

INSTALLATION

Screw
Plugs