User Response
Complete the following steps:
1. Inspect and reseat operator information panel cable at both ends.
2. Verify that the Baseboard Management Controller (BMC) is working.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
Lenovo Support website
–
Latest level of DSA
• 180-901-000 : Check-point Panel Test Failed
Check-point Panel Test Failed. Operator reported incorrect display.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check the operator information panel cabling for loose or broken connections at both ends or
damage to the cable.
2. Replace the information panel cable if damage is present.
3. Run the test again.
4. Replace the operator information panel assembly.
5. Run the test again.
6. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
Lenovo Support website
–
Latest level of DSA
DSA CPU stress test results
The following messages can result when you run the CPU stress test.
Test results for the DSA CPU stress test
The following messages can result when you run the DSA CPU stress test.
• 089-000-000 : CPU Stress Test Passed
CPU Stress Test Passed.
Recoverable