If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Replace power supply n. (n = power supply number)
PS2 12V OV Fault : PS2 12V UV Fault : PS2 12Vaux Fault :
• 80070614-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (TPM Phy
Pres Set)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706142201ffff or 0x800706142201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
1. Update the server firmware (see Recovering the server firmware).
2. If the problem persists, (trained technician only) replace the system board (see Removing the
system board and Installing the system board).
• 80080025-3701ffff : Device [LogicalDeviceElementName] has been removed from unit
[PhysicalPackageElementName]. (Thermal Board)
This message is for the use case when an implementation has detected a Device was removed.
May also be shown as 800800253701ffff or 0x800800253701ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0537
Lenovo System x3250 M6 Installation and Service Guide