Mitsubishi Electric Evolution+ s-MEXT Technical Manual page 102

Table of Contents

Advertisement

Par.N.
23.66
Pressure regulation differential for Constant Flow
23.67
Constant DeltaP adjustment setpoint
23.69
Pressure regulation differential for Constant DeltaP
23.68
Minimum internal fan speed in constant DeltaP (maximum nominal speed
reduction)
23.70
Fan analogue outlet variation step
23.72
Start-up of the fan at maximum speed if the adjustment starts with the return
temperature higher than the corresponding setpoint (0:Disabled –
1:Enabled)
23.81
Fan speed percentage during the restart phase
24.01
Room temperature probe calibration
24.02
Room humidity probe calibration
24.03
Delivery air temperature probe calibration
24.04
External air temperature probe calibration
24.08
Circuit 1 low pressure probe transducer
24.09
Inlet temperature probe 1 calibration
24.10
Circuit 2 low pressure probe transducer
24.11
Inlet temperature probe 2 calibration
24.20
Serial temperature probe address 129 calibration
24.21
Serial humidity probe address 129 calibration
24.40
Remote serial temperature 2 TH probe calibration
24.41
Remote serial humidity 2 TH probe calibration
24.42
Remote serial temperature 3 TH probe calibration
24.43
Remote serial humidity 3 TH probe calibration
24.44
Remote serial temperature 4 TH probe calibration
24.45
Remote serial humidity 4 TH probe calibration
24.23
Temperature differential for the update of the reading of probe T+H 128
24.24
Humidity differential for the update of the reading of probe T+H 128
24.50
Humidity differential for the update of the reading of the delivery T+H probe
24.51
Temperature differential for the update of the reading of the delivery T+H
probe
24.25
Temperature differential for the update of the reading of probe T+H 129
24.26
Humidity differential for the update of the reading of probe T+H 129
24.27
Temperature differential for the update of the reading of remote 2 T+H probe
24.28
Humidity differential for the update of the reading of remote 2 T+H probe
24.29
Temperature differential for the update of the reading of remote 3 T+H probe
24.30
Humidity differential for the update of the reading of remote 3 T+H probe
24.31
Temperature differential for the update of the reading of remote 4 T+H probe
24.32
Humidity differential for the update of the reading of remote 4 T+H probe
24.33
Return T+H temperature probe calibration
24.34
Return temperature 2 T+H probe calibration
24.35
Return temperature 3 T+H probe calibration
24.36
Return temperature 4 T+H probe calibration
Version 38
Description
Default
U.M.
Min.
25
Pa
5
10
Pa
5
5
Pa
3
20
%
0
1
Vdc
0
0
-
0
0
%
P
23.05
0
°C
-9.9
0
%RH
-20
0
°C
-9.9
0
°C
-9.9
0
bar
-9.9
0
°C
-9.9
0
bar
-9.9
0
°C
-9.9
0
°C
-9.9
0
%RH
-20
0
°C
-9.9
0
%RH
-20
0
°C
-9.9
0
%RH
-20
0
°C
-9.9
0
%RH
-9.9
0.1
°C
0.1
0.1
%RH
0.1
0.5
°C
0.1
0.5
%RH
0.1
0.1
°C
0.1
0.1
%RH
0.1
0.5
°C
0.1
0.5
%RH
0.1
0.5
°C
0.1
0.5
%RH
0.1
0.5
°C
0.1
0.5
%RH
0.1
0
°C
-9.9
0
°C
-9.9
0
°C
-9.9
0
°C
-9.9
Max.
100
300
50
P
10.11
5
1
P
23.01
9.9
20
9.9
9.9
9.9
9.9
9.9
9.9
9.9
20
9.9
20
9.9
20
9.9
9.9
2
2
2
2
2
2
2
2
2
2
2
2
9.9
9..9
9.9
9.9
102