Line Supply/Load Connection - Siemens SINAMICS S120 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Line Connection Booksize
2.4 Basic Line Filter for Active Line Modules with line reactor
The line/load connection must not be interchanged.
2.4.3.2

Line supply/load connection

Table 2-2
Type of connection
Terminals
Line supply connection (line supply)
Load connection (load)
Basic Line Filter for Active Line Modules
16 kW
36 kW
55 kW
1) for ring cable lugs to DIN 46234
44
WARNING
Designations
L1, L2, L3, PE
L1´, L2´, L3´, PE
Screw terminal: 10 mm
PE connection: M6/6 Nm
Screw terminal: 35 mm
PE connection: M6/6 Nm
Screw terminal: 50 mm
PE connection: M6/6 Nm
3-pin/1.5 -1.8 Nm (see Screw Terminals chapter)
2
1)
2
1)
/6 - 8 Nm
2
1)
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Booksize power units

Advertisement

Table of Contents
loading

Table of Contents