3.2.7

Technical data

Table 3-10
Technical data of Active Line Modules
Internal air cooling
Rated power
Infeed:
Rated power (S1)
1)
Infeed power (S6-40%)
Peak infeed power
1)
Regenerative feedback:
Continuous regenerative power rating
Peak regenerative power rating
Line supply voltages:
Line voltage
Line frequency
Electronics power supply
DC link voltage
Overvoltage trip threshold
Undervoltage trip threshold
Rated input current:
at 380 V
AC
at 480 V
/528 V
AC
AC
at 480 V; S6-40%)
Peak current (at 400 V
AC
DC link current:
Rated current
at S6-40%
Peak current
DC link busbar current carrying
capacity
24 V busbar current carrying capacity A
Electronics current consumption
Total power loss
(including electronic losses)
Max. ambient temperature
without derating
Max. ambient temperature
with derating
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
6SL3130–
kW
kW (Pn)
kW (Ps6)
1)
kW (Pmax)
kW
kW
V
ACrms
Hz
V
DC
V
DC
V
DC
V
DC
A
AC
A
AC
A
AC
/480 V
)
A
AC
AC
A
DC
A
DC
A
DC
A
DC
DC
A
DC
W
2)
°C
°C
3.2 Active Line Modules with internal air cooling
7TE21–6AAx
7TE23–6AAx
16
36
16
36
21
47
35
70
16
36
35
70
380 3 AC -10% (-15% < 1 min) to 480 3 AC +10%
47 to 63
24 (20.4 - 28.8)
510 - 720
820 ± 2%
360 ± 2%
26
58
21/19
46/42
27
60
54/45
107/89
27
60
35
79
59
117
100
200
20
20
1.1
1.5
286.4
666
40
40
55
55
Line Modules Booksize
7TE25–5AAx
7TE25–5AA3 +
Active Interface
Module
55
55
55
55
71
71
91
110
55
55
91
110
88
88
70/64
70/64
92
92
139/116
168/140
92
92
121
121
152
176
200
200
20
20
1.9
1.9
945.6
945.6
40
40
55
55
167