8.2

DC link rectifier adapter for Booksize format

8.2
8.2.1

Description

The DC link rectifier adapter supplies the DC link voltage directly. With a direct supply, each
component is connected to the DC link separately. The internal DC link busbar is not used
here.
The connection cables must be fused accordingly.
Note
When a DC link supply adapter and DC busbars are used, the limit values for radio
interference emission of category C2 to EN 61800-3 cannot be observed.
It is not possible to use the DC link rectifier adapter in conjunction with internal DC link
busbars.
Table 8-6
The DC link rectifier adapter is available in two sizes
for Line/Motor Modules with a width of
50 mm and 100 mm
6SL3162-2BD00-0AA0
Screw terminals (0.5 to 10 mm²)
8.2.2

Safety information

Risk of electric shock. A hazardous voltage is present for up to 5 minutes after the power
supply has been disconnected.
This time must elapse before any work may be carried-out on the adapter (e.g.
mounting/installation).
When opening the protective cover for the DC link, you must activate the release.
A suitable tool (e.g. screwdriver) must be used for this purpose.
The components must only be operated when the protective cover of the DC link is closed.
Damaged components must not be used further, as this could result in secondary damage
or accidents.
It is only permissible to establish connections to the DC link using the adapters that
SIEMENS has recommended (DC link adapter and DC link rectifier adapter).
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
DANGER
DANGER
8.2 DC link rectifier adapter for Booksize format
for Line/Motor Modules with a width of
150 mm, 200 mm, 300 mm
6SL3162-2BM00-0AA0
Screw terminals (35 to 95 mm²)
Accessories