Siemens SINAMICS S120 Equipment Manual page 31

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Modules
Line Modules in booksize format
Rated supply voltage
Rated pulse frequency
(for Active Line Modules in booksize format only)
Motor Modules in booksize format
DC link connection voltage
Rated pulse frequency
Environmental conditions
The Safety-Integrated safety function:
The components must be protected against conductive pollution (e.g. by installing them in a cabinet with degree of
protection IP54B acc. to EN 60529).
Provided that conductive pollution can be prevented at the installation site, the degree of protection for the cabinet can be
decreased accordingly.
Degree of protection
Protection class for network current circuits
Protection class for electronic circuits
Permissible coolant temperature (air) and installation
altitude during operation
Chemically active substances
Long-term storage in the transport packaging
Transport in the transport packaging
Operation
Biological environmental conditions
Long-term storage in the transport packaging
Transport in the transport packaging
Operation
Vibratory load
Long-term storage in the transport packaging
Transport in the transport packaging
Operation
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
480 V 3 AC
For intallation altitudes above 2000 m see the characteristic
for voltage derating
8 kHz
510 V DC up to 720 V
4 kHz
For higher pulse frequencies the corresponding
characteristic for current derating must be taken into
consideration.
IP20 or IPXXB to EN 60529,
open type to UL508
I (with protective conductor connection) and
III (protective extra low voltage DVC A/PELV) acc. to
EN 61 800-5-1
0 °C to +40 °C and an installation altitude of up to 1000 m
without derating,
>40 °C to +55 °C see the characteristic for current derating.
Installation altitude >1000 m up to 4000 m see characteristic
for current derating or reduction of the ambient temperature
by 3.5 K per 500 m.
Class 1C2 to EN 60721-3-1
Class 2C2 to EN 60721-3-2
Class 3C2 to EN 60721-3-3
Class 1B1 to EN 60721-3-1
Class 2B1 to EN 60721-3-2
Class 3B1 to EN 60721-3-3
Class 1M2 to EN 60721-3-1
Class 2M3 to EN 60721-3-2
Test values:
Frequency range: 10 Hz to 58 Hz
With constant deflection of 0.075 mm
Frequency range: 58 Hz to 200 Hz
With constant acceleration of 1 g
System Overview
1.7 System data
31

Advertisement

Table of Contents
loading