Printronix P8000 Plus Series Administrator's Manual page 96

Table of Contents

Advertisement

FF After Job
Determines the print position after an operator-initiated local copy (print screen function).
Off (factory default). Performs an automatic new line command after completing a print buffer (unless
a new line, form feed, or carriage return command was the last one executed). The printer is set to
print at print position 1 of the next line.
On. Performs an automatic form feed command unless a form feed was the last one executed. The
printer is set to print at print position 1 of the first line on the next form.
CR, EM, and NL (3287 only)
CR (Carriage Return), EM (Error Message), and NL (New Line) specify that the printer treat the CR, EM,
and NL control codes either as spaces or as control codes.
On (factory default). Treats the CR, EM, and NL commands as control codes.
Off. Treats the CR, EM, and NL commands as spaces.
Host Override
Determines whether the printer accepts certain commands sent by the host, or continues to use the
current operator panel settings.
Disable (factory default). Allows these host commands to override operator panel settings: line
length, forms length, lines per inch (LPI), characters per inch (CPI), print quality, and text orientation.
Note the information appearing on the message display may not match the data stream setting. No
values will change upon initial selection of the disable option.
Enable. The operator panel settings override the host commands.
Format Control
Enables the printer to reflect the same spacing as CTPC model printers after absolute and relative move
commands are executed.
Disable (factory default). Reflects distance, generated by the VGL feature, PGL feature, and Hex
Transparent control code sequence, in the new position (after horizontal and vertical tabs are
executed).
Enable.
Max. Print Width
Set the maximum print width the printer will print when using a C/T host interface. Set for 13.2 inches
when printing files larger than the width of the printer. All data exceeding the width of the maximum
Printer Width will be truncated.
13.2 inches (factory default)
Printer Width (the maximum width of the printer)