7 MAINTENANCE

7.3 Maintenance Intervals

7.3-1 Daily Maintenance Tasks
Daily
1
Check hydraulic oil level (figure 7.7-3, p-68)
2
Check engine oil level
3
Check fuel level (gauge on instrument panel)
4
Check fan belt tension / condition
5
Check track tension / condition
6
Check for proper control operation
7
Check for proper switch and lighting operation
8
Check / clean air cleaner elements
9
General visual check for cracks, damage, completeness
10
Check for leaks in hoses, tubes, valves, pumps, cylinders, etc.
11
Drain water separator
12
Lubricate all grease points
13
Inspect / clean the radiator/cooler and engine compartment
7.3-2 50-1000 hour Tasks
Every 50 operating hours
1
Inspect drive sprocket rollers (replace as needed)
Every 250 operating hours
1
Replace engine oil & filter
2
Replace hydraulic filter(s)
Every 500 operating hours
1
Replace fuel filter element
Every 1000 operating hours
1
Replace hydraulic oil
2
Replace engine coolant (use SCA additive, see engine manual)