General Information; Pre-Operation Safety Checklist - Terex R190T Operation And Maintenance Manual

Compact: track loader
Table of Contents

Advertisement

5.1 General Information

Operating a Terex Compact Track Loader is intended to be as safe and simple as
possible. This section expands on the machine controls portion of the manual and
also covers safe operation procedures to follow while operating.

5.2 Pre-Operation Safety Checklist

Before operating the machine, perform a pre-operation safety check. Inspect the
machine for any items that may affect safe operation.
Check to make sure:
1.
Engine compartment, chassis and coolers are clean and free of debris.
2.
Windows and lights are clean and unobstructed.
3.
Tracks are in good condition and are properly tensioned.
4.
Fluids are filled to proper levels.
5.
Accessory belts are in good condition and properly tensioned.
6.
Hydraulic hoses and fittings are in good condition. (no visible signs of wear)
Never use bare hands to check for leaks! Pressurized oil can penetrate
skin and cause gangrene. Seek medical attention immediately from a
physician familiar with this type of injury!
7.
Battery cables are in good condition and properly fastened.
8.
Joysticks, auxiliary hydraulic switch are in neutral position. Power quick
attach switch (if present) must be in the locked position.
9.
The R.O.P.S./F.O.P.S. approved operator enclosure is not damaged or
distorted structurally in any way.
10. The seat belt and lap bar restraint (if equipped) are in good working order.
11. All safety signs are in place and legible on the machine.
12. All control devices are present, appear to be in good condition, and are not
damaged in any way.
13. The safety circuit is functioning properly by performing the following:
A. Start the engine according to section 5.3.
B. Raise the lap bar, then attempt to curl the bucket.
C. Lower the lap bar.
D. Raise yourself off of the seat to remove pressure from the operator
presence safety switch located in the seat, then attempt to curl the
bucket.
If the bucket moves during either of these tests, the safety circuit is not
functioning properly. It must be repaired prior to operation.
15. You have read and understood the information in this manual in its entirety.
47
5 OPERATION
R160T / R190T US O&M
0404-490 2014-06

Advertisement

Table of Contents
loading

This manual is also suitable for:

R160t

Table of Contents