CONFIDENTIAL

ESC = n

[Name]
Set peripheral device
[Format]
ASCII
Hex
Decimal
1 £ n £ 3
[Range]
[Description] Selects device to which host computer sends data, using n as follows:
Bit
Off/On
0
Off
On
1
Off
On
2-7
-
· When the printer is disabled, it ignores all data except for error-recovery
[Notes]
commands (DLE ENQ 1, DLE ENQ 2, DLE EOT, DLE EOT BS, DLE ENG,
and DLE DC4) until it is enabled by this command.
[Default]
Serial interface specification
· When turning on the printer:
Direct Connection Customer Display Status
Customer display is recognized (*1)
Customer display is not recognized (*1)
· When executing ESC @:
Default values set by ESC @ are as follows, depending on the value set by
ESC = just before processing ESC @ and on the setting of DIP switch 2-2:
Direct Connection Customer Display Status
Default Value to be Set
When customer display is connected (*1)
After ESC @
Processing
When customer display is not connected (*1)
(*1) Depending on the setting of DIP switch 2-2.
(*2) The printer is disabled and it does not process ESC @; therefore, the ESC = setting is
changed.
Parallel interface specification: n = 1
[Reference]
DLE ENQ
ESC
=
1B
3D
27
61
Hex
Decimal
Function
00
0
Printer disabled.
01
1
Printer enabled
00
0
Customer display disabled.
02
2
Customer display enabled.
-
-
Undefined.
TITLE
TM-H5000 II II II II series
Specification
(STANDARD)
n
n
n
n
2
1
n
1
2
1
2(*2)
1
2(*2)
NO.
SHEET
REVISION
NEXT
E
3
2
1