3.3.8.2 Restore Limit Stops with the Keyboard

To restore the electronic limit stops to factory settings with the keyboard:
1. Press [Set].
2. Press [N] where "N" represents the number which corresponds to the preset being
restored. Reference Table 3-3 to determine which number to use to change each
electronic limit stop.
Store Preset
70
71
72
73
3. Press [Pre]. The electronic limit has been adjusted back to the factory default.

3.4 Unstowing the Positioner

The customer must set preset position [2] before this function can be used.
To unstow the positioner:
1. Power on the system.
2. Perform the pre-operation check (Section 3.1).
3. Press [2].
4. Press [Pre]. The positioner will move to the preset unstowed position. When moving
to the unstowed position, the positioner will first tilt and then pan. As the positioner
nears the unstowed position, it will slow down. If an emergency stop is required as
the positioner is moving to position, move the joystick to cancel out the command.
The system is unstowed and ready for use.
PM-01011-A
October 2023

Table 3-3 Default Limit Stop Numbers

Function
Restores default counterclockwise limit
Restores default clockwise limit
Restores default up limit
Restores default down limit