2.8 Setting Presets and Electronic Limit Stops

Electronic limit stops can be set within the positioner as part of the installation process.
Setting electronic limit stops prevents the positioner from travelling past a specified point in
either tilt or pan direction. The user has the option to set electronic limit stops for the tilt up,
tilt down, pan right and/or pan left directions. Electronic limit stops can be cleared by the
user. Electronic limit stops can be set and cleared using a Pelco D compatible joystick
controller or a GUI. Electronic limit stops are assigned by setting presets 80, 81, 82 and 83.
Electronic limit stops are cleared by setting presets 70, 71, 72 and 73. See Sections 3.3.7,
Electronic Limit Stops3.3.8Error! Reference source not found., and 6.2.
IMPORTANT!
If the tilt limit stops are cleared to their default settings, it is possible
to drive the payload platform into the power/data connector. This will cause damage
to the positioner.
Presets can be set within the positioner to store a specified position. The user can store [1] -
[50] presets. Presets can be cleared or over overwritten. Presets can be set, cleared, or
overwritten using a Pelco D compatible joystick controller or a GUI. Preset [0] is designated
for the "Factory Home" position and cannot be reset. Preset [1] and Preset [2] is designated
for the "Stow" and "Unstow" position and are set by the user. See Sections 3.3.7 and 6.2 for
more details.