3.3.1 GUI Installation

To install a new version of the GUI on you selected device (PC, Laptop, Tablet, etc.) you
must first uninstall any previous version located on the device that you are installing to.
A copy of the most up to date GUI will be provided with the Positioner.

3.3.2 GUI Setup Instructions

3.3.2.1 Easysync Setup.

Connect 1x Easysync ES-U-3001-M Unit to your Laptop/ PC/ Tablet using the USB
connection cable.
o Set to RS485 Half duplex by switching the white Dip Switches on the
Easysync unit.
o Settings: Up/Dn/Dn/Dn
o Connect the Data A & B cables from the positioner to ports 1 & 2 on the
Easysync unit.

3.3.2.2 WB Positioner Setup.

Press the "Select Com Port 1" drop down menu and select the Com Port the unit/
converter is connected to.
Press "UPDATE SETTINGS" for the unit to update all the necessary settings, the
GUI will start updating the settings and this process should take approximately 30
seconds. Once the settings are updated all the boxes underneath the "UPDATE
SETTINGS" and "Read Input Voltage" will go green.
If the sections do not go green as shown in figure 3-1 above, then swap the
connection of Data cables A & B which are in port 1 & 2 on the Easysync unit.
Press "UPDATE PARAMS" which will update all the parameters set. Once all the
parameters are updated all the boxes underneath the "UPDATE PARAMS" will go
green.
To change the address of the unit, enter the address number within the box shown in
the picture above marked as 4 and press "Set New Address" to save the setting onto
the unit.