Air Lift 27691 Instruction Manual page 59

Kit specific component list
Table of Contents

Advertisement

3H/3P User Guide
System Messages
Label
Corner height sensor
CAUTION
near limit (FL, FR, RL,
RR*)
CAUTION
Compressor freeze
CAUTION
Compressor overheat
Tank pressure
CAUTION
sensor failure
CAUTION
Tank pressure too low
Adjusting minimum ride
DANGER
height below 25% may
result.....
MN-948
Fault
Height sensor range is near limit of operation at the given
corner.
The system has detected no increase in tank pressure
when compressor commanded on and compressor may
be blocked.
The compressor duty cycle has been reached and
excessive usage has been detected which could overheat
the compressor.
The system detected a pressure sensor failure at the
manifold block for the tank sensor.
System will disable the compressor when a tank pressure
sensor failure has been detected to eliminate the
opportunity of overfilling the tank.
Tank pressure has fallen below 85 PSI. Will reset when
pressure reaches 85 PSI.
Setting the minimum driving height below the 25% default
may result in vehicle damage and personal injury. Agreeing
to and understanding this safety concern will allow the
system to be set below 25%.
Problem
21