Calibration Detail Explained

AUTO SENSOR LIMITS
When the program is completing the auto sensor calibration, make
sure the wheels are straight and all people stand clear as the
vehicle will move up and down during calibration. The user doesn't
have to do anything during this portion of the calibration.
MANUAL SENSOR LIMITS
Below is what is being completed during the wizard's manual
sensor calibration. Use this option when making a custom setup
where there may be concern about component interference at
either high or low limits. (e.g. Wheel to fender interference – if the
system is aired out and the wheel and fender make contact before
the suspension can reach its limit.)
1. Set upper limit
Use the manual buttons to set the upper height sensor
limit.
Press the ride preset button to continue.
2. Set lower limit
Use the manual buttons to set the lower height sensor
limit.
Press the middle button to continue.
3. Calibration is complete.
PRESSURE
Below is what the wizard is doing during the pressure calibration.
1 . Front calibration – The system actuates the suspension
through its range of travel to calibrate pressure mode on the
front axle.
2 . Rear calibration – The system actuates the suspension
through its range of travel to calibrate pressure mode on the
rear axle.
3. At any time, cancel calibration by selecting "stop."