Air Lift 27691 Instruction Manual page 49

Kit specific component list
Table of Contents

Advertisement

3H/3P User Guide
Setup, Cont.
COMPRESSOR (SETUP, CONT .)
DUAL/SINGLE
Set based on whether a dual or single
compressor setup is installed. If using a
second compressor and harness, dual must be
selected for proper operation.
1. Single (default)
2. Dual
MAX PRESSURE
Set the maximum tank pressure. The
compressor will turn on at 15 PSI below max
tank pressure.
1. 150-200 PSI or 10342-13789 mBAR
2. Holding the up or down button quickly
cycles between 150 PSI/10342 mBAR
and 200/13789. A single press changes
pressure one increment at a time.
3. 150 PSI (default)
DUTY CYCLE
This is for the user to set the compressor duty cycle.
WARNING
See Page 22 for compressor duty cycle and working pressure .
1.
33%
2. 50% (default)
3. 66%
MINIMUM BATTERY VOLTAGE
Set minimum battery voltage required to allow compressor to turn on.
1. 10-14 volts
2. 11 volts (default)
FACTORY RESET
Resets all settings and calibration back to factory default.
1. Cancel (default)
2. Reset all
Cycle ignition to complete the factory reset.
MN-948
Setting the duty cycle higher than the manufacturer's
recommended value may cause compressor damage.
4. 75%
5. 100%
11